DVD 22 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 13

Read Harman Kardon DVD 22 EMC - CB Certificate online

 
 
page 11 of 35 
Ref.No.: 312941   
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
 
 
14.3.4.1 
Class 
ΙΙ transformers have adequate separation 
between hazardous live windings and accessible 
windings (double or reinforced insulation) 
TR1  
Prim. – Sec.= 6.1 mm  
Reinforced 
 
Coil formers and partition walls 
≥ 0.4 mm 
1mm P 
14.3.4.2 
Class 
Ι transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
 N 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 N 
14.3.5.1 
Class 
ΙΙ transformers have adequate insulation 
between hazardous live windings and accessible 
parts (double or reinforced insulation) 
Iron core in TR1 not connected 
to acc. parts. 
 
Coil formers and partition walls 
≥ 0.4 mm 
 P 
14.3.5.2 
Class 
Ι transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
 N 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N 
14.4 
High voltage components 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
No high-voltage component 
 
Component meets category FV 1 of IEC 60707 
 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 N 
14.5 
Protective devices 
 
Protective devices used within their ratings 
 
 
External clearance and creepage distances 
appropriate for the voltage across the device when 
opened 
 P 
Page of 109