WOORI Technology Inc.                                                Page 10 of 118 
                               DPR2005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 267.EMS 
 
 
8. Immunity to ambient electromagnetic fields (S3) 
 
8.1 Test criteria and test procedure 
 
      Operating environment; 
 Temperature 
20  ℃ 
 
Relative Humidity 
40 % 
 
      The EUT was placed on a non-metallic support,0.1m above the lower conductor in the center 
   of the stripline. 
 
      The wanted signal was fed to all input terminals respectively.      The unwanted signal is fed to 
        a matching network of the strip line. 
 
      The criterion concerning acceptable sound interference is a wanted to unwanted audio signal   
      ratio of  ≥40 dB at a wanted signal level of 50 mW. 
 
      The audio output power was measured with a 0.5 - 3 kHz band-pass filter. 
      The ground connection of the mains filter (M) was directly connected to the jacky. 
 
      The audio analyzer was applied without a weighting filter. 
 
   The measurements were performed with test software TS9980 Ver.2.9. 
 
8.2 Measurement uncertainty 
 
     Radiated fields  : +/- 2dB 
 
8.3 Test result immunity to conducted voltage. 
 
        The equipment does comply with the requirements. 
 
    For the measurement data, see Annex D 
 