Read Harman Kardon DPR 2005 (serv.man2) EMC - CB Certificate online
WOORI Technology Inc. Page 14 of 118
DPR2005 (Harman Kardon)
EMC Test Report
Reference No.: NK2EE 267.EMS
11. Radio-frequency, Electromagnetic Field Keyed Carrier Immunity test (ENV 50204)
11.1 Test criteria and test procedure
Operating environment;
Temperature:
20 ℃
Relative Humidity:
40 %
The tests were performed at 3m distance in an anechoic chamber.
For floor-standing equipment, the EuT was standing on the floor, isolated from the ferrite core.
For tabletop equipment, the EuT was located on a wooden table 0.8m above the floor.
The EuT was exposed to the field from different angles, normally 0。, 90。,180。,270。 and 360。
and at both horizontal and vertical polarization (antenna height 1.5m).
A signal level of 3V/m, 50% PM modulated with a 200Hz was applied in the frequency range
895 - 905MHz.
Instrumentation used during this session:
Instruments
Manufacturer
Model
Serial Number
Due to Calibration
Signal Generator
R & S
SMY01
1062.5502.11
2004. 12
Power Amplifier
Noiseken
NA25MF1G2010C
A00518
2005. 02
Power Sensor
HP
8482A
U537293323
2005. 02
Power Meter
HP
E4419B
GB39511164
2005. 04
Biconical log Antenna
ARA
LPB-2520/A
1180
2005. 02
Wideband field probe
Chase
EMC-20
2244190.2
2005. 03
11.2 Test Parameters
Port:
Enclosure
Test Engineer:
J. Y. Yu
Basic Standard: EN 61000-4-3:1995
Performance Criteria:
A
Dwell Time :
3 Sec
Frequency Step :
1%
Modulation :
50% Duty PM @ 200 Hz
Frequency Range :
895-905 MHz
Test Level
3 Vrms