DPR 1005 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 44

Read Harman Kardon DPR 1005 (serv.man13) EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 40 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
 
FAULT CONDITION TESTS (Continued) 
P
Comp. 
No 
Fault Test 
Point Test 
time 
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
PC101 
S-c 
253 
Pin 3 - 4 
(Pri. side)
 
30 min 
F101 
0,96 A 
Normal operated. 
Input current stabilised at 0,96A. 
No component damaged. 
No hazard. 
PC101 
S-c 
253 
Pin 1 - 2 
(Sec. side)
 
10 min 
F101 
0,10 A 
Unit shut down immediately. 
Input current stabilised at 0,10 A. 
No component damaged. 
No hazard. 
AMP 
module 
installed 
FAN 
Locked 253 
45 
min  F101
 
0,96 A 
Protection circuit in AMP module 
operated after 42 min. 
Input current stabilised at 0,14 A. 
No component damaged. 
No hazard.
 
Front 
speaker 
terminal 
S-c 
253 
R - G 
10 min 
F101
 
0,14 A 
Unit shut down immediately. 
Input current stabilised at 0,14 A. 
No component damaged. 
No hazard.
 
Pmax. 
opening 
- 253 
- 3 
hr 
F101
 
3,86 A 
Components are heated-up to (
∆t);
- T101 coil 
: 80K 
- T101 core 
: 62K 
- T102 coil 
: 44K 
- T102 core 
: 40K 
- T103 coil  
: 71K 
- T201 coil 
: 48K 
- T201 core 
: 46K 
- T202 coil 
: 47K 
- T202 core 
: 45K 
- LF101 coil 
: 30K 
- LF102 coil 
: 31K 
and stabilised.  
Input current stabilised at 3,86 A. 
Dielectric strength test O.K. 
No hazard
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 