No.
26088
FAULT CONDITION TESTS (Continued)
P
Comp.
No
No
Fault Test
V
Point Test
time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
D214
S-c
253
A - C
10 min
F101
0,10 A
Unit shut down immediately.
Input current stabilised at 0,10 A.
No component damaged.
No hazard.
Input current stabilised at 0,10 A.
No component damaged.
No hazard.
C222
S-c
253
-
10 min
F101
0,10 A
Unit shut down immediately.
Input current stabilised at 0,10 A.
No component damaged.
No hazard.
Input current stabilised at 0,10 A.
No component damaged.
No hazard.
D217
S-c
253
A - C
10 min
F101
2,00 A
Unit shut down after 2 sec.
Input current stabilised at 0,10 A.
D216 damaged.
No hazard.
Input current stabilised at 0,10 A.
D216 damaged.
No hazard.
C225
S-c
253
-
10 min
F101
0,10 A
Unit shut down immediately.
Input current stabilised at 0,10 A.
D217 damaged.
No hazard.
Input current stabilised at 0,10 A.
D217 damaged.
No hazard.
D218
S-c
253
AC – (+)
30 min
F101
0,96 A
Normal operated.
Input current stabilised at 0,96A.
No component damaged.
No hazard.
Input current stabilised at 0,96A.
No component damaged.
No hazard.
C229
S-c
253
-
1 hr
F101
0,97 A
Normal operated.
Input current stabilised at 0,97A.
No component damaged.
No hazard.
Input current stabilised at 0,97A.
No component damaged.
No hazard.
Q203
S-c
253
E - B
30 min
F101
0,96 A
Normal operated.
Input current stabilised at 0,96A.
No component damaged.
No hazard.
Input current stabilised at 0,96A.
No component damaged.
No hazard.
Q203
S-c
253
E - C
10 min
F101
1,12 A
Output signal off after 3 sec.
Input current stabilised at 0,37A.
R223 opened.
No hazard.
Input current stabilised at 0,37A.
R223 opened.
No hazard.
PC102
S-c
253
Pin 3 - 4
(Pri. side)
10 min
F101
0,10 A
Unit shut down immediately.
Input current stabilised at 0,10 A.
No component damaged.
No hazard.
Input current stabilised at 0,10 A.
No component damaged.
No hazard.
PC102
S-c
253
Pin 1 - 2
(Sec. side)
10 min
F101
0,10 A
Unit shut down immediately.
Input current stabilised at 0,10 A.
No component damaged.
No hazard.
Input current stabilised at 0,10 A.
No component damaged.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection