DPR 1005 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 43

Read Harman Kardon DPR 1005 (serv.man13) EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 39 of 41 - 
 
 
   
 Order 
No. 
26088
 
 
 
 
 
FAULT CONDITION TESTS (Continued) 
P
Comp. 
No 
Fault Test 
Point Test 
time 
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
D214 
S-c 
253 
A - C 
10 min 
F101 
0,10 A 
Unit shut down immediately. 
Input current stabilised at 0,10 A. 
No component damaged. 
No hazard. 
C222 
S-c 
253 
10 min 
F101 
0,10 A 
Unit shut down immediately. 
Input current stabilised at 0,10 A. 
No component damaged. 
No hazard. 
D217 
S-c 
253 
A - C 
10 min 
F101 
2,00 A 
Unit shut down after 2 sec. 
Input current stabilised at 0,10 A. 
D216 damaged. 
No hazard. 
C225 
S-c 
253 
10 min 
F101 
0,10 A 
Unit shut down immediately. 
Input current stabilised at 0,10 A. 
D217 damaged. 
No hazard. 
D218 
S-c 
253 
AC – (+) 
30 min 
F101 
0,96 A 
Normal operated. 
Input current stabilised at 0,96A. 
No component damaged. 
No hazard. 
C229 
S-c 
253 
1 hr 
F101 
0,97 A 
Normal operated. 
Input current stabilised at 0,97A. 
No component damaged. 
No hazard. 
Q203 
S-c 
253 
E - B 
30 min 
F101 
0,96 A 
Normal operated. 
Input current stabilised at 0,96A. 
No component damaged. 
No hazard. 
Q203 
S-c 
253 
E - C 
10 min 
F101 
1,12 A 
Output signal off after 3 sec. 
Input current stabilised at 0,37A. 
R223 opened. 
No hazard. 
PC102 
S-c 
253 
Pin 3 - 4 
(Pri. side)
 
10 min 
F101 
0,10 A 
Unit shut down immediately. 
Input current stabilised at 0,10 A. 
No component damaged. 
No hazard. 
PC102 
S-c 
253 
Pin 1 - 2 
(Sec. side)
 
10 min 
F101 
0,10 A 
Unit shut down immediately. 
Input current stabilised at 0,10 A. 
No component damaged. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 