AVR 8500 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 42

Read Harman Kardon AVR 8500 (serv.man2) EMC - CB Certificate online

 
IEC 60065, 6th edition : 1998
 - 
- Page 38 of 44 - 
 
 
   
 
Order No. 
200211174
 
 
 
 
 
FAULT CONDITION TESTS (continued)   
Comp. 
No 
Fault 
Test V 
Position 
Test time  Fuse No 
Current 
through 
fuse 
Mains power/temperatures/results 
C480 
S-c 
207 
30 min 
F454, 
F455 
2,43 A 
FL display off immediately. 
F454, F455 opened. 
Input current stabilised at 2,22A. 
No hazard.   
C481 
S-c 
254,4 
3 hr 
F454, 
F455 
2,55 A 
FL display off immediately. 
Input current stabilised at 2,52A. 
Sub transformer primary winding 
heated-up to 59K and stabilised. 
No hazard.   
D473 
S-c 
254,4 
A - C 
30 min 
2,46 A 
Normal operating. 
No component damaged. 
No hazard. 
C484 
S-c 
254,4 
3 hr 
F454, 
F455 
2,56 A 
FL display off immediately. 
R455 opened. 
Input current stabilised at 2,54A. 
Sub transformer primary winding 
heated-up to 69K and stabilised. 
No hazard.   
Q460 
S-c 
254,4 
C - E 
30 min 
2,46 A 
Normal operating. 
No component damaged. 
No hazard. 
Q460 
S-c 
254,4 
B - C 
30 min 
2,46 A 
Normal operating. 
No component damaged. 
No hazard. 
D476 
S-c 
254,4 
A - C 
30 min 
2,46 A 
Normal operating. 
No component damaged. 
No hazard. 
D506 
 
S-c 
254,4 
AC - + 
30 min 
F452, 
F501, 
F502 
Normal operating. 
F501 opened immediately. 
Input current stabilised at 2,46A. 
No hazard.   
C704 
S-c 
254,4 
30 min 
F452, 
F501, 
F502 
Protection circuit operated 
immediately (
RLY452, RLY453
 off). 
F501, F502 opened. 
Input current stabilised at 0,02A. 
No hazard.   
C704 
S-c 
207 
30 min 
F452, 
F501, 
F502 
Protection circuit operated 
immediately (
RLY452, RLY453
 off). 
F501, F502 opened. 
Input current stabilised at 0,02A. 
No hazard.   
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
Page of 55