Read Harman Kardon AVR 8500 (serv.man2) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 37 of 44 -
Order No.
200211174
FAULT CONDITION TESTS
P
Ambient temperature
24,8 °C
Rated voltage
230V~ 50Hz
Remarks
-
Comp.
No
No
Fault
Test V
Position
Test time Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
D452
S-c
254,4
~ - +
1 sec
F452
-
F452 opened immediately.
No hazard.
No hazard.
D452
S-c
207
~ - +
1 sec
F452
-
F452 opened immediately.
No hazard.
No hazard.
C457
S-c
254,4
-
1 sec
F452
-
F452 opened immediately.
No hazard.
No hazard.
C457
S-c
207
-
1 sec
F452
-
F452 opened immediately.
No hazard.
No hazard.
D455
S-c
254,4
A - C
30 min
F453
-
Output signal off immediately.
FL display off.
F453 opened.
No hazard.
FL display off.
F453 opened.
No hazard.
C466
S-c
254,4
-
30 min
F453
-
Output signal off immediately.
FL display off.
F453 opened.
No hazard.
FL display off.
F453 opened.
No hazard.
C466
S-c
207
-
30 min
F453
-
Output signal off immediately.
FL display off.
F453 opened.
No hazard.
FL display off.
F453 opened.
No hazard.
C468
S-c
254,4
-
30 min
F453
0,07
Output signal off immediately.
FL display off.
F453 opened after 10 sec.
No hazard.
FL display off.
F453 opened after 10 sec.
No hazard.
C468
S-c
207
-
30 min
F453
0,05
Output signal off immediately.
FL display off.
F453 opened after 20 min.
R453 damaged.
No hazard.
FL display off.
F453 opened after 20 min.
R453 damaged.
No hazard.
D469
S-c
254,4
A - C
30 min
F454,
F455
F455
2,80 A
FL display off after 9 sec.
F454, F455 opened.
Input current stabilised at 2,50A.
No hazard.
F454, F455 opened.
Input current stabilised at 2,50A.
No hazard.
C480
S-c
254,4
-
30 min
F454,
F455
F455
2,80 A
FL display off immediately.
F454, F455 opened.
Input current stabilised at 2,46A.
No hazard.
F454, F455 opened.
Input current stabilised at 2,46A.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
Click on the first or last page to see other AVR 8500 (serv.man2) service manuals if exist.