Read Harman Kardon AVR 8500 (serv.man2) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 30 of 44 -
Order No.
200211174
16.6
Apertures for external flexible cord:
no risk of damage to the cord during
assembly or movement in use
no risk of damage to the cord during
assembly or movement in use
Appliance inlet provided
N
16.7
Transportable musical instruments
and assosiated amplifiers fitted with
detachable cord set with appliance
inlet to IEC 60 320-1
and assosiated amplifiers fitted with
detachable cord set with appliance
inlet to IEC 60 320-1
Appliance inlet provided
N
Transportable musical instruments
and amplifiers fitted with cord and
with means of stowage to protect the
cord
and amplifiers fitted with cord and
with means of stowage to protect the
cord
N
17
ELECTRICAL CONNECTIONS AND
MECHANICAL FIXINGS
MECHANICAL FIXINGS
P
17.1
Torque test to Table 12:
P
Screw
Diameter
With
Without
Material
Torque test (Nm)
Location/function
(mm)
head
head
Screw
Nut
Fulfilled /Remarks
Top enclosure (side)
4
x
Metal
Metal
Tested with 1,2Nm /
Pass
Pass
Top enclosure (rear)
3
x
Metal
Metal
Tested with 0,5Nm /
Pass
Pass
17.2
Correct introduction into female
threads in non-metallic material
threads in non-metallic material
No female threads in non-metallic materials
N
17.3
Cover fixing screws: captive
Captivity not necessary, see below
P
Non-captive fixing screws: no hazard
when replaced by a screw whose
length is 10 times its diameter
when replaced by a screw whose
length is 10 times its diameter
Tested with screw with 10 times diameter.
P
17.4
No loosening of conductive parts
carrying a current > 0,2 A
carrying a current > 0,2 A
Loosening is sufficiently prevented
P
17.5
Contact pressure not transmitted
through plastic other than ceramic
for connections carrying a current
> 0,2 A
through plastic other than ceramic
for connections carrying a current
> 0,2 A
No contact pressure transmitted through insulating
material.
material.
P
17.6
Stranded conductors of flexible
supply cords carrying a current
> 0,2 A with screw terminals not
consolidated by solder
supply cords carrying a current
> 0,2 A with screw terminals not
consolidated by solder
Appliance inlet provided
N
Click on the first or last page to see other AVR 8500 (serv.man2) service manuals if exist.