Read Harman Kardon AVR 8500 (serv.man2) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 28 of 44 -
Order No.
200211174
15.3.3
Screws and nuts clamping external
mains supply conductors have
adequate threads: ISO 261, ISO 262
or similar
mains supply conductors have
adequate threads: ISO 261, ISO 262
or similar
No screws and nuts clamping
N
15.3.4
Soldered conductors wrapped
around terminal prior to soldering or
held in place by additional means
around terminal prior to soldering or
held in place by additional means
Appliance inlet provided
N
Clamping of conductor and insulation
if not soldered or held by screws
if not soldered or held by screws
N
15.3.5
Terminals for external flexible cords
shall allow connection of appropriate
cross-sectional area of conductors
for the rated current of the equipment
shall allow connection of appropriate
cross-sectional area of conductors
for the rated current of the equipment
Terminals have adequate connection capacity.
P
15.3.6
Terminals to 15.3.3 have sizes
required by Table 8
required by Table 8
The terminals have adequate size according to table 8
P
15.3.7
Terminals clamp conductors
between metal surfaces
between metal surfaces
Terminals have adequate pressure without damage the
conductor.
conductor.
P
Terminals designed to avoid
conductor slipping out when
tightened or loosened
conductor slipping out when
tightened or loosened
Adequate construction
P
Terminals adequately fixed to avoid
loosening when the clamping is
tightened or loosened and stress on
internal wiring is avoided
loosening when the clamping is
tightened or loosened and stress on
internal wiring is avoided
Terminals adequately fixed and clearances and creepage
are not reduced blow required values.
No stress on internal wiring.
are not reduced blow required values.
No stress on internal wiring.
P
15.3.8
Terminals carrying a current more
than 0,2 A: contact pressure not
transmitted by insulating material
except ceramic
than 0,2 A: contact pressure not
transmitted by insulating material
except ceramic
No contact pressure transmitted through insulating
material.
material.
P
15.3.9
Termination of non-detachable cords:
wires terminated near to each other
wires terminated near to each other
Appliance inlet provided
N
Terminals located and shielded: test
with 8 mm strand
with 8 mm strand
N
15.4
Devices forming a part of the mains
plug
plug
N
15.4.1
No undue strain on mains socket-
outlets
outlets
The apparatus is not a device forming a part of the mains
plug.
plug.
N
15.4.2
Device complies with standard for
dimensions of mains plugs
dimensions of mains plugs
N
15.4.3.
Device has adequate mechanical
strength (tests a,b,c)
strength (tests a,b,c)
N
Click on the first or last page to see other AVR 8500 (serv.man2) service manuals if exist.