Read Harman Kardon AVR 760 (serv.man3) EMC - CB Certificate online
- Page 2 of 4 -
Report
No.
106189
13.3 – 13.4 Clearances and Creepage distances
P
Type
of
Insulation
Position/
Location
Location
Position/
Location
Location
Working
Voltage (V)
Clearance (mm)
13.3.2
Creepage dist
(mm) 13.4
Comm.
1
2
Up
Urms
Req.
Measu.
Req.
Measu.
Basic
Line
Neutral
340
240
2,0 mm
6,5 mm
2,5 mm
6,5 mm
1), 3), 4)
Basic
Line
Neutral
340
240
2,0 mm
3,0 mm
2,5 mm
3,0 mm
2), 5)
Basic
Line
Neutral
340
240
2,0 mm
3,1 mm
2,5 mm
3,1 mm
1), 6)
Reinforce Primary Secondary 411
291
4,0 mm
8,0 mm
6.2 mm
8,0 mm
2), 7)
Reinforce
Primary
Chassis
340
240
4,0 mm
7,7 mm
5,0 mm
7,7 mm
8)
Reinforce
Primary
Chassis
340
240
4,0 mm
9,5 mm
5,0 mm
>9,5 mm 9)
Note: U in Volt, Clearances/Creepage Distances in mm, Comm.=Comment
Comments: 1) Measured on PCB (top side).
2) Measured on PCB (bottom side).
3) Before mains fuse.
4) Measured on appliance inlet (JA3000) trace between line and neutral.
5) Measured on outlet (JA3001) trace between line and neutral.
6) Measured on P3006 connector trace between line and neutral.
7) Measured from F3001 primary trace to C3101 secondary trace.
8) Measured between pri. trace for socket outlet and near metal chassis (back cover)
9) Measured between primary solder pin and metal chassis (bottom)
3) Before mains fuse.
4) Measured on appliance inlet (JA3000) trace between line and neutral.
5) Measured on outlet (JA3001) trace between line and neutral.
6) Measured on P3006 connector trace between line and neutral.
7) Measured from F3001 primary trace to C3101 secondary trace.
8) Measured between pri. trace for socket outlet and near metal chassis (back cover)
9) Measured between primary solder pin and metal chassis (bottom)
Click on the first or last page to see other AVR 760 (serv.man3) service manuals if exist.