AVR 760 (serv.man3) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 82

Read Harman Kardon AVR 760 (serv.man3) EMC - CB Certificate online

 
 
- Page 2 of 4 - 
 
 
 
 Report 
No. 
106189
 
 
 
13.3 – 13.4  Clearances and Creepage distances 
Type  
of  
Insulation 
Position/ 
Location 
Position/ 
Location 
Working 
Voltage (V) 
Clearance (mm) 
13.3.2 
Creepage dist  
(mm) 13.4 
Comm.
Up 
Urms
Req. 
Measu. 
Req. 
Measu. 
Basic 
Line 
Neutral 
340 
240 
2,0 mm 
6,5 mm 
2,5 mm 
6,5 mm 
1), 3), 4)
Basic 
Line 
Neutral 
340 
240 
2,0 mm 
3,0 mm 
2,5 mm 
3,0 mm 
2), 5) 
Basic 
Line 
Neutral 
340 
240 
2,0 mm 
3,1 mm 
2,5 mm 
3,1 mm 
1), 6) 
Reinforce Primary Secondary 411 
291 
4,0 mm 
8,0 mm 
6.2 mm 
8,0 mm 
2), 7) 
Reinforce 
Primary 
Chassis 
340 
240 
4,0 mm 
7,7 mm 
5,0 mm 
7,7 mm 
8) 
Reinforce 
Primary 
Chassis 
340 
240 
4,0 mm 
9,5 mm 
5,0 mm 
>9,5 mm  9) 
 
 
 
 
 
 
 
 
 
 
Note: U in Volt, Clearances/Creepage Distances in mm, Comm.=Comment 
Comments:  1) Measured on PCB (top side).  
2) Measured on PCB (bottom side).  
3) Before mains fuse. 
4) Measured on appliance inlet (JA3000) trace between line and neutral. 
5) Measured on outlet (JA3001) trace between line and neutral. 
6) Measured on P3006 connector trace between line and neutral. 
7) Measured from F3001 primary trace to C3101 secondary trace. 
8) Measured between pri. trace for socket outlet and near metal chassis (back cover)  
9) Measured between primary solder pin and metal chassis (bottom)  
 
 
Page of 91