Read Harman Kardon AVR 760 (serv.man3) EMC - CB Certificate online
- Page 1 of 4 -
Report
No.
106189
ATTACHMENT: Tables to EN/IEC 60065 7
th
edition.
9.1.1.1
Touch current expressed as voltages U1 and U2 in Annex D
P
Location Measured
U1V
(peak)
(peak)
Measured
U1
V (DC)
U1
V (DC)
Measured
U2
V (peak)
U2
V (peak)
Limits :
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
Mains pole 1 – Antenna Terminal
-
-
0,03V
Pass
Mains pole 2 – Antenna Terminal
-
-
0,04V
Pass
Mains pole 1 – Other part and contact
-
-
0,03V
Pass
Mains pole 2 – Other part and contact
-
-
0,04V
Pass
Comments:
See clause 9.1.1.1
Test condition, Vin = 264Vac / 60Hz
Only U2 have been recorded due to the use of linear transformers in power supply.