Read Harman Kardon AVR 760 (serv.man3) EMC - CB Certificate online
- Page 39 of 45 -
Report
No.
106189
Monitored point:
Under fault conditions specified below
Under fault conditions specified below
dT (K)
Limit dT
(K)
*), Q334 (C to E), S-c;
Unit shut down immediately. Input current stabilised at 0,06A.
Q336, Q328, Q324, Q232 damaged. R374, R372, R376 opened.
No hazard. (Tested time: 10 min)
Unit shut down immediately. Input current stabilised at 0,06A.
Q336, Q328, Q324, Q232 damaged. R374, R372, R376 opened.
No hazard. (Tested time: 10 min)
N/A N/A
**), Q336 (C to E), S-c;
Unit shut down immediately. Input current stabilised at 0,02A.
Q334 damaged. No hazard. (Tested time: 10 min)
Unit shut down immediately. Input current stabilised at 0,02A.
Q334 damaged. No hazard. (Tested time: 10 min)
N/A N/A
*), Q336 (C to B), S-c;
Unit shut down immediately. Input current stabilised at 0,02A.
Q334, Q336 damaged. No hazard. (Tested time: 10 min)
Unit shut down immediately. Input current stabilised at 0,02A.
Q334, Q336 damaged. No hazard. (Tested time: 10 min)
N/A N/A
*), C304, S-c;
Surround right output off immediately. Input current stabilised at 3,05A.
R352, R304, R368 opened. No hazard (Tested time: 30 min)
Surround right output off immediately. Input current stabilised at 3,05A.
R352, R304, R368 opened. No hazard (Tested time: 30 min)
N/A N/A
*), D3005 (A to C), S-c;
Unit shut down after 2 min 30 sec.
Sub transformer primary winding heated up to 140.2K and thermal
fuse opened. Input current stabilised at 0,01A.
Dielectric strength test O.K. No hazard. (Tested time: 2 min 30 sec)
Unit shut down after 2 min 30 sec.
Sub transformer primary winding heated up to 140.2K and thermal
fuse opened. Input current stabilised at 0,01A.
Dielectric strength test O.K. No hazard. (Tested time: 2 min 30 sec)
Sub transf.
140.2 K
Sub transf.
150 K
*), C3025, S-c;
Unit shut down immediately.
Sub transformer primary winding heated up to 140.0K and thermal
fuse opened after 2 min 40sec. Input current stabilised at 0,01A.
Dielectric strength test O.K. No hazard. (Tested time: 2 min 40 sec)
Unit shut down immediately.
Sub transformer primary winding heated up to 140.0K and thermal
fuse opened after 2 min 40sec. Input current stabilised at 0,01A.
Dielectric strength test O.K. No hazard. (Tested time: 2 min 40 sec)
Sub transf.
140.0 K
Sub transf.
150 K
*), C3102, S-c;
Unit shut down after 3 sec. Input current stabilised a t 0,06A.
F3001 fuse opened. D3101 damaged.
No hazard. (Tested time: 10 min)
Unit shut down after 3 sec. Input current stabilised a t 0,06A.
F3001 fuse opened. D3101 damaged.
No hazard. (Tested time: 10 min)
N/A N/A
*), D3101 (AC to “+”), S-c;
Unit shut down immediately. Input current stabilised at 0,06A.
F3001 opened. D3101 damaged. No hazard. (Tested time: 1 sec)
Unit shut down immediately. Input current stabilised at 0,06A.
F3001 opened. D3101 damaged. No hazard. (Tested time: 1 sec)
N/A N/A
**), D3101 (AC to “-”), S-c;
Unit shut down immediately. Input current stabilised at 0,02A.
F3001 opened. D3101 damaged. No hazard. (Tested time: 1 sec)
Unit shut down immediately. Input current stabilised at 0,02A.
F3001 opened. D3101 damaged. No hazard. (Tested time: 1 sec)
N/A N/A
*), C152, S-c;
Unit shut down immediately. Input current stabilised at 0,06A.
F3001 opened. No hazard. (Tested time: 1 sec)
Unit shut down immediately. Input current stabilised at 0,06A.
F3001 opened. No hazard. (Tested time: 1 sec)
N/A N/A
*), D4000 (AC to “+”), S-c;
Unit shut down immediately. Input current stabilised at 0,06A.
F3001 opened. No hazard (Tested time: 1 sec)
Unit shut down immediately. Input current stabilised at 0,06A.
F3001 opened. No hazard (Tested time: 1 sec)
N/A N/A
*) Tested voltage 264V
**) Tested voltage 207V
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded