Read Harman Kardon AVR 760 (serv.man3) EMC - CB Certificate online
- Page 37 of 45 -
Report
No.
106189
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ......... :
264V or 207V
—
Ambient temperature (
o
C) ................................... :
23-26
o
C
—
Monitored point:
Under fault conditions specified below
Under fault conditions specified below
dT (K)
Limit dT
(K)
*), D801 (AC to “+”), S-c;
Normal operated. Input current stabilised at 3,40A.
F802 opened. No hazard. (Tested time: 30 min)
Normal operated. Input current stabilised at 3,40A.
F802 opened. No hazard. (Tested time: 30 min)
N/A N/A
**), D801 (AC to “+”), S-c;
Normal operated. Input current stabilised at 3,29A.
F802 opened. No hazard. (Tested time: 10 min)
Normal operated. Input current stabilised at 3,29A.
F802 opened. No hazard. (Tested time: 10 min)
N/A N/A
*), D801 (AC to “-“), S-c;
Normal operated. Input current stabilised at 3,40A.
F801 opened. No hazard. (Tested time: 10 min)
Normal operated. Input current stabilised at 3,40A.
F801 opened. No hazard. (Tested time: 10 min)
N/A N/A
*), C806, S-c;
Unit shut down immediately. Input current stabilised at 0,06A.
F801, F802 opened. No hazard. (Tested time: 10 min)
Unit shut down immediately. Input current stabilised at 0,06A.
F801, F802 opened. No hazard. (Tested time: 10 min)
N/A N/A
*), D220 (AC to “+”), S-c;
All output signal off immediately. Input current stabilised at 1,17A.
F221 opened. No hazard. (Tested time: 30 min)
All output signal off immediately. Input current stabilised at 1,17A.
F221 opened. No hazard. (Tested time: 30 min)
N/A N/A
**), D220 (AC to “+”), S-c;
All output signal off immediately. Input current stabilised at 0,87A.
F221 opened. No hazard. (Tested time: 10 min)
All output signal off immediately. Input current stabilised at 0,87A.
F221 opened. No hazard. (Tested time: 10 min)
N/A N/A
*), D220 (AC to “-“), S-c;
All output signal off immediately. Input current stabilised at 1,12A.
F220 opened. No hazard. (Tested time: 10 min)
All output signal off immediately. Input current stabilised at 1,12A.
F220 opened. No hazard. (Tested time: 10 min)
N/A N/A
*), C224, S-c;
All output signal off immediately. Input current stabilised at 1,13A.
F221 opened. No hazard. (Tested time: 10 min)
All output signal off immediately. Input current stabilised at 1,13A.
F221 opened. No hazard. (Tested time: 10 min)
N/A N/A
**), C224, S-c;
All output signal off immediately. Input current stabilised at 1,13A.
F221 opened. No hazard. (Tested time: 10 min)
All output signal off immediately. Input current stabilised at 1,13A.
F221 opened. No hazard. (Tested time: 10 min)
N/A N/A
*), IC232 (pin 1 to 2), S-c;
Normal operated. Input current stabilised at 3,42A.
No component damaged. No hazard. (Tested time: 30 min)
Normal operated. Input current stabilised at 3,42A.
No component damaged. No hazard. (Tested time: 30 min)
N/A N/A
*), D140 (AC to “+”), S-c;
Unit shut down immediately. Input current stabilised at 0,06A.
F103 opened. No hazard. (Tested time: 10 min)
Unit shut down immediately. Input current stabilised at 0,06A.
F103 opened. No hazard. (Tested time: 10 min)
N/A N/A
*) Tested voltage 264V
**) Tested voltage 207V
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded
Click on the first or last page to see other AVR 760 (serv.man3) service manuals if exist.