Read Harman Kardon AVR 760 (serv.man2) EMC - CB Certificate online
Harman Kardon Inc. Page 14 of 192
AVR760 (Harman Kardon)
EMC Test Report
Reference No.: NK08E 683.EMS
11. Radio-frequency, Electromagnetic Field Keyed Carrier Immunity test (EN61000-4-3)
11.1 Test criteria and test procedure
Operating environment;
Temperature:
23 ℃
Relative Humidity:
40 %
The tests were performed at 3m distance in an anechoic chamber.
For floor-standing equipment, the EUT was mounted non-conducting support 0.1 m above the
supporting plane. For tabletop equipment, the EUT was located on a wooden table 0.8 m above the floor.
The EUT was exposed to the field from different angles, normally 0°, 90°, 180°, 270°
and at both horizontal and vertical polarization(antenna height 1.75 m)
A signal level of 3 V/m, duty cycle 1/8 pulse modulated with a 217 Hz sine wave was applied in the
frequency range 900 MHz. During the test the 1 kHz unwanted noise level comes from the speaker was
detected using microphone and selected level meter
For floor-standing equipment, the EUT was mounted non-conducting support 0.1 m above the
supporting plane. For tabletop equipment, the EUT was located on a wooden table 0.8 m above the floor.
The EUT was exposed to the field from different angles, normally 0°, 90°, 180°, 270°
and at both horizontal and vertical polarization(antenna height 1.75 m)
A signal level of 3 V/m, duty cycle 1/8 pulse modulated with a 217 Hz sine wave was applied in the
frequency range 900 MHz. During the test the 1 kHz unwanted noise level comes from the speaker was
detected using microphone and selected level meter
Instrumentation used during this session:
Instruments
Manufacturer
Model
Serial number Due to Calibration
Signal Generator
R & S
SMY01
830766/032
2009.03
Function Generator
H.P
33120A
US36042890
2009.01
Power Amplifier
Noiseken
NA25MF1G2010C
A00518
2009.10
Power Amplifier
Noiseken
NA15K80M50C
A00518
2009.10
Power Sensor
HP
8482A
US37293322
2009.03
Power Sensor
HP
8482A
US37293323
2009.03
Power Meter
HP
E4419B
GB39511164
2009.03
Biconical log Antenna
ARA
LPB-2520/A
1180
2009.01
Selective Level Meter
Anritsu
ML422B
M18572
2009.06
11.2 Test Parameters
Port:
Enclosure
Test Engineer:
J. Y. Yu
Basic Standard: EN 61000-4-3:2002+A1: 2002
Performance Criteria:
A
Dwell Time :
120 sec
Frequency Range :
900 MHz
Modulation :
1/8 Duty PM @ 217 Hz
Test Level
3 Vrms