AVR 760 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 115

Read Harman Kardon AVR 760 (serv.man2) EMC - CB Certificate online

 
Harman Kardon Inc.                                                Page 11 of 192 
                                                                            AVR760 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK08E 683.EMS 
 
 
9. Screening effectiveness (S4) 
 
9.1 Test criteria and test procedure 
 
      Operating environment; 
 Temperature 
22  ℃ 
 
Relative Humidity 
40 % 
 
      The equipment under test was placed on a non-metallic table of height 0.8 M. 
      At the side of the antenna input terminal of the equipment under test, a non-metallic table   
        of length 4 M was placed at the same height to provide for movement of the measuring   
    device, an absorbing clamp.  
   An RF signal generator is placed on a third table. 
 
      The equipment under test is connected to the generator, but not connected to the mains supply. 
      The signal from the generator is at the test frequency and un-modulated. 
 
9.2 Measurement uncertainty 
 
     Radiated fields  : +/- 2 dB 
 
9.3 Test result immunity to conducted voltage. 
 
        The equipment does comply with the requirements. 
 
    For the measurement data, see Annex E 
 
Page of 127
Display

Click on the first or last page to see other AVR 760 (serv.man2) service manuals if exist.