Read Harman Kardon AVR 7500 (serv.man9) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 16 of 43 -
Order No.
200211175
11.2.1
Measurement of temperature rises
See appended table, fault condition tests
P
11.2.2
Temperature rise of accessible parts
See appended table, fault condition tests
P
11.2.3
Temperature rise of parts, other than
windings, providing electrical insulation
windings, providing electrical insulation
See appended table, fault condition tests
P
Temperature rise of printed circuit boards
(PCB) exceeding the limits of Table 2 by
max. 100 K for max. 5 min
(PCB) exceeding the limits of Table 2 by
max. 100 K for max. 5 min
No area where temperature exceeds 100K above
limits
limits
P
a) Temperature rise of printed circuit
boards (PCB) to 20.1.3, exceeding the
limits of Table 2 by not more than 100 K
for an area not greater than 2 cm²
boards (PCB) to 20.1.3, exceeding the
limits of Table 2 by not more than 100 K
for an area not greater than 2 cm²
No area where temperature exceeds 100K above
limits
limits
P
b) Temperature rise of printed circuit
boards (PCB) to 20.1.3 up to 300 K for
an area not greater than 2 cm² for a
maximum of 5 min
boards (PCB) to 20.1.3 up to 300 K for
an area not greater than 2 cm² for a
maximum of 5 min
No area where temperature exceeds 300K above
limits
limits
P
Meets all the special conditions if
conductors on printed circuit boards are
interrupted
conductors on printed circuit boards are
interrupted
No conductors are interrupted/peeled/loosened during
fault conditions
fault conditions
N
11.2.4
Temperature rise of parts acting as a
support or mechanical barrier
support or mechanical barrier
Temperature rises are within the limits.
P
11.2.5
Temperature rise of windings
See Fault Condition tests
P
11.2.6
Temperature rise of parts not subject to
the limits of 11.2.1 to 11.2.5,
table 2 item e).
the limits of 11.2.1 to 11.2.5,
table 2 item e).
No excessive temperature observed/measured on
other parts.
other parts.
P
12
MECHANICAL STRENGTH
P
12.1.1
Bump test (>7kg)
No damage in the sense of this standard
P
12.1.2
Vibration test (portable, musical
amplifiers, metal enclosure)
amplifiers, metal enclosure)
Assessed to be satisfactory constructed.
N
12.1.3
Impact test (0.5J)
No damage in the sense of this standard
P
12.2
Fixing of knobs, push buttons, keys and
levers
levers
Normal use will not impair the protection against
electric shock.
electric shock.
P
12.3
Remote controls with hazardous live
parts
parts
No remote control containing hazardous live parts
N
12.4
Drawers (pull test 50 N, 10 s)
No drawers
N
12.5
Antenna coaxial sockets providing
isolation
isolation
No antenna socket which insolate hazardous live
parts from accessible parts.
parts from accessible parts.
N
Click on the first or last page to see other AVR 7500 (serv.man9) service manuals if exist.