AVR 660 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 10

Read Harman Kardon AVR 660 (serv.man2) EMC - CB Certificate online

 
Harman Kardon Inc.                                                Page 9 of 103 
                                                                          AVR760 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK08E 683.EMI 
 
6. Mains Terminal Continuous Disturbance Voltage &   
Conducted Disturbance at the telecommunication port
 
 
6.1 Test Procedure (EN55013) 
The measurements were performed in a shielded enclosure. EUT was connected to an Artificial Mains 
Network (AMN). EUT was placed on a wooden table 0.8 m above the grounded floor and at least 0.4 m 
from the reference ground plane (wall), EUT was placed at least 0.8m from, and connected via a 1m mains 
cable, to the AMN. The output power of the amplifier was set to 1/8 of rated power at 8 ohms load. 
        The measurements on the terminals for mains connection were conducted between neutral and ground, and 
between phase and ground, in the frequency range 150 kHz to 30 MHz. 
        A peak detector scan was conducted over the defined frequency range on all phases. A comparison of the 
results obtained from the different phases was then conducted to find the most emitting phase for each 
frequency.    This “Worst Case” scan with peak detector is presented detector. 
        Instrumentation used during this session: 
 
6.2 Test Procedure (EN55022) 
The measurements were performed in a shielded enclosure. The telecommunication port of an EUT was 
connected to a ISN described in CISPR 22:2005. EUT was placed on a wooden table 0.4 m above the 
grounded floor and at least 0.4 m from the reference ground plane (wall), EUT was placed at least 0.8 m from 
ISN. The measurement at telecommunication port was conducted in the frequency range 150 kHz to 30 MHz. 
        A peak detector scan was conducted over the defined frequency range.   
        This “Worst Case” scan with quasi-peak detector & average detector was presented detector. 
Instrumentation used during this session: 
 
Instruments Manufacturer 
Model 
Serial number
Due To Calibration 
Test Receiver   
R&S 
ESCS30 100302 
2008. 
12 
Artificial Mains Network 
R&S 
ESH3-Z5 
833874/006 
2009. 10 
LISN Kyoritsu 
KNW-407 
8-1034-10 
2009. 
02 
Impedance Stabilization 
Network 
TESEQ GMBH 
ISN T400 
24330 
2009. 05 
 
6.3 Measurement Uncertainty 
 
    Mains terminal disturbance voltage measurement         : ±3.0 dB 
 
6.4 Test Parameters 
 
Port: 
AC Mains
 
Test Engineer: 
J. H. Ko 
Basic Standard: 
EN 55013: 2001+A1: 2003+A2: 2006 
 
Basic Standard: 
EN 55022: 2006 (Class B) 
 
Frequency Range: 
150 kHz – 30 MHz 
Frequency Step: 
5 kHz 
IF Bandwidth: 
9 kHz 
Measurement Time: 
0.2 sec 
 
Page of 127
Display

Click on the first or last page to see other AVR 660 (serv.man2) service manuals if exist.