AVR 660 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 9

Read Harman Kardon AVR 660 (serv.man2) EMC - CB Certificate online

 
Harman Kardon Inc.                                                Page 8 of 103 
                                                                          AVR760 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK08E 683.EMI 
 
5. Standards, Deviations and Results 
 
5.1 Applied Test Standards 
         
      The following standards have been applied: 
    ●  EN 55013: 2001+A1: 2003+A2: 2006 
        Limits and methods of measurement of radio disturbance characteristics of broadcast receivers and 
    Associated equipment 
Phenomena Basic 
Standards 
Result 
Mains terminal continuous disturbance voltage   
EN 55013: 2001+A1: 2003+A2: 2006 
Pass
 
Radio Interference Power 
EN 55013: 2001+A1: 2003+A2: 2006 
Pass 
Radiated Disturbance 
EN 55013: 2001+A1: 2003+A2: 2006 
Pass 
Antenna Terminal Disturbance Voltage 
EN 55013: 2001+A1: 2003+A2: 2006 
Pass 
 
EN 61000-3-2 : 2006 : 
  Electromagnetic compatibility (EMC)-Pt.3: Limits-S.2: Limits for harmonic-current emissions   
        (Equipment input current up to and including 16A) 
  Phenomena Basic 
Standards 
Result 
Steady State Harmonics 
EN 61000-3-2:2006 
N/A 
Fluctuating Harmonics 
EN 61000-3-2:2006 
Pass 
 
  EN 61000-3-3:1995+A1: 2001+A2: 2005 
  Electromagnetic compatibility (EMC)-Pt.3: Limits-S.3: Limits for voltage fluctuations and flicker   
        in low voltage supply systems for equipment with rated current up to and including 16A. 
Phenomena Basic 
Standards  Result 
Flicker 
EN 61000-3-3:1995+A1: 2001+A2: 2005 
Pass 
Voltage Fluctuations 
EN 61000-3-3:1995+A1: 2001+A2: 2005 
N/A 
 
EN 55022:2006 (Class B) :   
        Limits and methods of measurement of radio disturbance characteristics of information technology 
 Eequipment. 
Phenomena Basic 
Standards 
Result 
Conducted Disturbance at the mains ports   
EN 55022:2006 
N/A 
Conducted Disturbance at the telecommunication ports 
EN 55022:2006 
Pass
 
Radiated Disturbance   
EN 55022:2006 
N/A
 
 
5.2 Deviations and Evaluations 
 
        ●No recorded deviations to the applied standards. 
        ●No general evaluations made. 