AVR 5550 (serv.man11) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 10

Read Harman Kardon AVR 5550 (serv.man11) EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 8 of 40 - 
 
 
   
 Order 
No. 
200245265
 
 
 
 
7.1
 
 
 
Operating conditions (power audio amplifier, 1/8 of maximum non clipped output): 
 U 
= 
254,4
 V, I 
= 
 
2,57
 A, P 
= 
493 
Pout = 
2 x 10,1 
(F)
 
   
 
 
 
 
 
 
1 x 9,90
 W 
(C)
 
   
 
 
 
 
 
 
2 x 10,0
 W 
(S) 
   
 
 
 
 
 
 
2 x 10,0
 W 
(S/W)
 
 
 
 
LSL =
 
5 x 8
 
 
 
 
 
Marking of loudspeaker terminals 
SPEAKERS (8
Ω)
 
:
 SR, SL, FR, FL” 
   
 
”SPEAKERS (8
Ω)
 
:
  
   
 
CTR, SBR/MILTI R, SBL/MILTI L”
 
 
 
U =
 254,4 
V 
4 Ohm 
8 Ohm 
16 Ohm 
 
 Ohm 
 Left 
right 
left 
right 
left 
right
left 
right
Measured max. output voltage    in Vp 
  F) 
35,9 
C) 35,6 
S) 35,8 
S/W) 35,8
F) 35,9 
C) - 
S) 35,8 
S/W) 35,8 
 
 
 
 
Measured max. output power    in W
 
 
  F) 
80,6 
C) 79,4 
S) 80,0 
S/W) 80,5
F) 80,6 
C) - 
S) 80,0 
S/W) 80,5 
 
 
 
 
Measured max. mains power in W
 
 
 1170 
  
 
 
Operation of protective devices     
No fuse links operate during normal operating condition 
7.1.1 
Temperature rise of accessible parts 
(see table next page) 
7.1.2 
Temperature rise of parts providing 
electrical insulation   
(see table next page) 
7.1.3 
Temperature rise of parts acting as a 
support or as a mechanical barrier   
(see table next page) 
7.1.4 
Temperature rise of windings   
(see table next page) 
7.1.5 
Parts not subject to a limit under 
7.1.1 to 7.1.4   
(see table next page) 
Page of 51
Display

Click on the first or last page to see other AVR 5550 (serv.man11) service manuals if exist.