AVR 5550 (serv.man11) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 12

Read Harman Kardon AVR 5550 (serv.man11) EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 10 of 40 - 
 
 
   
 Order 
No. 
200245265
 
 
 
 
HEATING (continued) 
Other measured parts 
t measured 
at 207V 
t measured 
at 254,4V 
t allowed *) 
Power TR, Q437 body 
53,8 
63,4 
PWB near Q437 
51,6 
59,3 
85 
Fan 1, body (inner) 
22,4 
24,0 
60 
Fan 2, body (outer) 
37,0 
41,6 
60 
Main 
heat-sink 
42,6 47,3 - 
Appliance inlet body 
12,1 
13,2 
60 
Top enclosure above main heat-sink 
17,1 
18,1 
40 
Top enclosure above main transformer 
3,2 
3,6 
40 
Switch 
button 
0,9 2,4 50 
 
 
 
 
Comments  
 
 
No other parts were observed to create any hazard due to temperature rise.   
 
*) Temperature rise limits for Singapore is 10K less. 
 
 
 
 
 
 
 
 
7.2 
Softening temperature of insulating 
material supporting parts 
conductively connected to the mains 
carrying a current > 0,2 A at least 
150 
°
C  
No temperature measured during heating test and fault 
cond. tests requires this test (7.2) to be performed. 
Tested parts 
Temperature   
under normal 
operating con- 
ditions (°C) 
Temperature  
under fault 
conditions  
            (°C) 
Softening 
temperature 
            (°C) 
 
 
 
 
 
 
 
 
 
 
 
 
 