AVR 507 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 41

Read Harman Kardon AVR 507 (serv.man2) EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 37 of 38 - 
 
 
   
 Order 
No. 
11152
 
 
 
 
 
FAULT CONDITION TESTS (continued) 
Comp. 
No 
Fault Test 
Short 
current 
Test time
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
Q804 
S-c 
254,4 
C - E 
10 min 
F907 
F905 
F906 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
F905, F906 opened. 
Q903, Q804 shorted. 
No hazard. 
Q804 
S-c 
254,4 
B - C 
10 min 
F907 
F905 
F906 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
No component damaged. 
No hazard. 
C813 S-c 
254,4 - 
20 
min 
F907 
F905 
F906 
1,56 A 
Surround L channel signal output 
off immediately. 
Input current stabilised at 1,56A. 
No component damaged. 
No hazard. 
D962 
S-c 
254,4 
A - C 
15 min 
1,78 A 
Sub transformer primary winding 
heated-up to 109K thermal fuse 
opened after 15 min. 
Dielectric strength test O.K. 
No hazard. 
C906 
S-c 
254,4 
14 min 
< 0,03 A 
Mains relay off immediately. 
Sub transformer primary winding 
heated-up to 111K thermal fuse 
opened after 14 min. 
Dielectric strength test O.K. 
No hazard. 
C907 
S-c 
254,4 
1 hr 
< 0,02 A 
Mains relay off immediately. 
Sub transformer primary winding 
heated-up to 80K and stabilised. 
Dielectric strength test O.K. 
No hazard. 
Fan  
(Back cover)
 
Locked 254,4  - 
hr 
F907, 
F903, 
F904, 
F905, 
F906 
1,79 A 
Normal operating. 
The components are heated up to: 
- Main transf. pr. winding  : 70K 
- Main transformer core 
: 57K 
- Sub transf. pr. winding 
: 55K 
- Sub transformer core 
: 42K 
- D992 body 
: 55K 
- PWB near D992 
: 58K 
- Q803 body 
: 63K 
- PWB near Q804 
: 60K 
and stabilised. 
Dielectric strength test OK. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
Page of 50