Read Harman Kardon AVR 435 (serv.man4) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 36 of 38 -
Order
No.
39659
FAULT CONDITION TESTS (continued)
P
Comp.
No
No
Fault Test
V
Short
current
current
Test time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
D601
S-c
253
AC - +
30 min
F101
F601
F602
F601
F602
2,40 A
Normal operated.
Input current stabilised at 2,40A.
F601 opened. No hazard.
Input current stabilised at 2,40A.
F601 opened. No hazard.
C605 S-c
253 -
30
min
F101
F601
F602
F601
F602
2,41 A
Normal operated.
Input current stabilised at 2,41A.
F602 opened. No hazard.
Input current stabilised at 2,41A.
F602 opened. No hazard.
D201
S-c
253
AC - +
1 sec
F101
-
F101 opened immediately.
Input current stabilised at 0,02A.
No hazard.
Input current stabilised at 0,02A.
No hazard.
D201
S-c
207
AC - +
10 min
F101
0,02 A
Unit shut down immediately.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
C201
S-c
253
-
10 min
F101
0,02 A
Unit shut down immediately.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
Q334
S-c
253
E - C
10 min
F101
0,02 A
Unit shut down immediately.
Input current stabilised at 0,02A.
Q336 damaged. No hazard.
Input current stabilised at 0,02A.
Q336 damaged. No hazard.
Q334
S-c
253
B - C
10 min
F101
0,02 A
Unit shut down immediately.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
Q336
S-c
253
B - C
10 min
F101
0,02 A
Unit shut down immediately.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
Input current stabilised at 0,02A.
No component damaged.
No hazard.
Q336
S-c
253
E - C
10 min
F101
0,02 A
Unit shut down immediately.
Input current stabilised at 0,02A.
Q334 damaged. No hazard.
Input current stabilised at 0,02A.
Q334 damaged. No hazard.
C304
S-c
253
-
2 hr
F101
2,60 A
Normal operated.
Input current stabilised at 2,38A.
C306 vented and R304 opened and
R352 damaged. No hazard.
Input current stabilised at 2,38A.
C306 vented and R304 opened and
R352 damaged. No hazard.
C310
S-c
253
-
1 hr
F101
2,15 A
Surround R-ch output signal off
immediately.
Input current stabilised at 2,15A.
No component damaged.
No hazard.
immediately.
Input current stabilised at 2,15A.
No component damaged.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection