Report No.: 215445
ATTACHMENT 5
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Applicable to portable/wall socket-outlet and portable cable reel
20
Portable/wall
socket-outlet
and portable
cable reel
socket-outlet
and portable
cable reel
a) If residual current device (RCD)
is incorporated, its tripping current
must be less than 30mA and
operating time must be less than
0.1 second and testing to sub-
clauses 9.9.2.1, 9.9.2.2, 9.9.2.3 and
9.16 of SS 97: Part 1: 2000 are
required.
b) The shutters screening the
current-carrying socket contacts
shall not be opened by the insertion
of any corresponding SINGLE pin
of the plug into any current-carrying
socket aperture.
is incorporated, its tripping current
must be less than 30mA and
operating time must be less than
0.1 second and testing to sub-
clauses 9.9.2.1, 9.9.2.2, 9.9.2.3 and
9.16 of SS 97: Part 1: 2000 are
required.
b) The shutters screening the
current-carrying socket contacts
shall not be opened by the insertion
of any corresponding SINGLE pin
of the plug into any current-carrying
socket aperture.
No portable/wall socket-
outlet and portable
cable reel.
outlet and portable
cable reel.
N/A
21
Wall switched
socket-outlet
(2 x single
socket-outlet)
socket-outlet
(2 x single
socket-outlet)
Single socket-outlet with 2-gang
faceplate/frame must be fulfilled
with the test requirements as 2-gang
socket-outlet.
faceplate/frame must be fulfilled
with the test requirements as 2-gang
socket-outlet.
N/A
22
Remote
controlled
portable/wall
portable
socket-outlet
controlled
portable/wall
portable
socket-outlet
Remote controlled portable/wall
socket-outlet shall not be
allowed for registration.
socket-outlet shall not be
allowed for registration.
N/A
Applicable to roaster
22 Roaster
A metal ring (Appendix U) must be
provided to prevent the roaster from
falling off in case the glass bowl
shattered.
provided to prevent the roaster from
falling off in case the glass bowl
shattered.
No roaster.
N/A
Applicable to Residual Current Circuit Breaker (RCCB)
33 RCCB
Registration of RCCB is limited to
30 mA sensitivity and the operating
time must be less than 0.1 second.
Electronic RCCB will not be
accepted for registration.
30 mA sensitivity and the operating
time must be less than 0.1 second.
Electronic RCCB will not be
accepted for registration.
No Residual Current Circuit
Breaker.
Breaker.
N/A
Applicable to electric instantaneous and storage water heater
34
Instantaneous
electric water
heater and
mains
pressure
electric storage
water heater
electric water
heater and
mains
pressure
electric storage
water heater
Heating elements used must not be
of the "bare-element" type.
of the "bare-element" type.
No electric instantaneous
and storage water heater.
and storage water heater.
N/A
35
Water heater
incorporated
with residual
current
device(RCD)
incorporated
with residual
current
device(RCD)
Testing to sub-clauses 9.9.2.1,
9.9.2.2, 9.9.2.3 and 9.16 of SS 97:
Part 1: 2000 are required.
9.9.2.2, 9.9.2.3 and 9.16 of SS 97:
Part 1: 2000 are required.
N/A