Reference No. : 54120703A                                                                                                                        Page 17
 
◀  Anam EMC Test Laboratory  ▶
 
 
10. VOLTAGE FLUCTUATIONS-FLICKER 
   10.1. Operating environment 
Temperature 
: 25℃ 
Relative humidity  : 60% 
 
      10.2. Test set-up and procedure 
 
The open circuit test voltage was the rated voltage of the EUT. 
 
The reference impedance was a conventional impedance being used to calculate 
or measure the disturbance caused by an appliance. 
 
The measurement was performed with the Test software for Windows 
 
10.3. Test instrumentation 
Equipment 
Mfr. 
Type No. 
Serial No. 
R. C. Oscillator 
Kenwood 
AG-203A 
3090241 
Reference impedance 
Voltech 
IEC Standard 555 
IB16/0725 
Universal power analyzer  Voltech 
PM 3300 
AK19/7742 
Programmable controller 
Pacific 
360AMXT/UPC32 
151 
Magnetics module 
Pacific 
134310 
334 
 
10.4. Test result 
 
The equipment does comply with the requirements. 
 
For the measurement data, see Annex D (2 Copies). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 