Read Harman Kardon AVR 345 (serv.man2) EMC - CB Certificate online
Reference No. : 54120703A Page 16
◀ Anam EMC Test Laboratory ▶
9. HARMONICS
9.1. Operating environment
Temperature
: 20℃
Relative humidity : 45%
9.2. Test set-up and procedure
Harmonics of the fundamental current were measured up to 2 ㎑ using a
universal power analyzer. The measurement was carried out under steady
conditions and using averaging.
The Class of this equipment is “Class A” by clause 5 of EN61000-3-2 : 2000.
The measurement was performed with the Test software for Windows
The input signal and load conditions were set as given in clause 4.2.4 of
IEC 60065.
The input signal and load conditions were set as given in clause 4.2.4 of
IEC 60065.
9.3. Test instrumentation
Equipment
Mfr.
Type No.
Serial No.
R. C. Oscillator
Kenwood
AG-203A
3090241
Universal power analyzer Voltech
PM 3300
AK19/7742
Programmable controller
Pacific
360AMXT/UPC32
151
Magnetics module
Pacific
134310
334
9.4. Test result
The equipment does comply with the requirements.
For the measurement data, see Annex C (3 Copies).
For the measurement data, see Annex C (3 Copies).
Click on the first or last page to see other AVR 345 (serv.man2) service manuals if exist.