AVR 270 (serv.man6) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 10

Read Harman Kardon AVR 270 (serv.man6) EMC - CB Certificate online

Reference No. : 54121209A                                                                                                                  Page 10/43 
◀  Anam EMC Test Laboratory  ▶
 
 
Disturbance radiation due to the other source.   
Channel Harmonic 
Measured 
freq. (㎒) 
Limit 
(㏈㎶/m) 
Disturbance value(㏈㎶/m) 
Horizon Vertical 
  
122.28 
40.0 
29.2 
Others  159.75 
40.0 27.8  * 
  
208.89 
40.0 
32.4 
28.7 
 30 
221.18 
40.0 
33.7 28.3 
 
1,000  ㎒ 
479.23 
47.0 
34.6 33.8 
  
606.40 
47.0 
* 38.2 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
*: More than margin 7.0 ㏈㎶/m 
 
Limit according to EN55013:2001+A2(2006)
 
 
 
7. ANTENNA TERMINAL DISTURBANCE VOLTAGE IN THE   
  FREQUENCY RANGE 30MHz TO 1,000MHz
 
 
  7.1. Operating environment 
Temperature 
: 28℃ 
Relative humidity  : 37% 
 
    7.2. Test set-up and procedure 
Measurements were performed in the frequency range 30 ㎒ to 1,000 ㎒. 
 
The level of the test signal, which was connected to the receiver through a 
combining network, was set to give 70 ㏈㎶  at the input of the EUT. 
The signal was an unmodulated carrier. 
Disturbance voltage due to the local oscillator, it’s fundamental and harmonic 
frequencies was measured with the receiver tuned to a selected number of FM 
sound broadcast channels. Disturbance voltage due to all other sources was 
measured with the receiver tuned to the channel 98.3 ㎒ respectively. 
 
   7.3. Measurement uncertainty 
 
Antenna terminal disturbance voltage, Quasi-peak detection:  ±2.0 ㏈ 
 
The measurement uncertainty describes the overall uncertainty of the given 
 
measured value during the operation of the EUT in the above-mentioned way. 
 
Page of 43
Display