Read Harman Kardon AVR 270 (serv.man6) EMC - CB Certificate online
Reference No. : 54121209A Page 10/43
◀ Anam EMC Test Laboratory ▶
Disturbance radiation due to the other source.
Channel Harmonic
Measured
freq. (㎒)
Limit
(㏈㎶/m)
Disturbance value(㏈㎶/m)
Horizon Vertical
122.28
40.0
*
29.2
Others 159.75
40.0 27.8 *
208.89
40.0
32.4
28.7
30
~
221.18
40.0
33.7 28.3
1,000 ㎒
479.23
47.0
34.6 33.8
606.40
47.0
* 38.2
*: More than margin 7.0 ㏈㎶/m
Limit according to EN55013:2001+A2(2006)
7. ANTENNA TERMINAL DISTURBANCE VOLTAGE IN THE
FREQUENCY RANGE 30MHz TO 1,000MHz
7.1. Operating environment
Temperature
: 28℃
Relative humidity : 37%
7.2. Test set-up and procedure
Measurements were performed in the frequency range 30 ㎒ to 1,000 ㎒.
The level of the test signal, which was connected to the receiver through a
combining network, was set to give 70 ㏈㎶ at the input of the EUT.
The signal was an unmodulated carrier.
Disturbance voltage due to the local oscillator, it’s fundamental and harmonic
frequencies was measured with the receiver tuned to a selected number of FM
sound broadcast channels. Disturbance voltage due to all other sources was
measured with the receiver tuned to the channel 98.3 ㎒ respectively.
combining network, was set to give 70 ㏈㎶ at the input of the EUT.
The signal was an unmodulated carrier.
Disturbance voltage due to the local oscillator, it’s fundamental and harmonic
frequencies was measured with the receiver tuned to a selected number of FM
sound broadcast channels. Disturbance voltage due to all other sources was
measured with the receiver tuned to the channel 98.3 ㎒ respectively.
7.3. Measurement uncertainty
Antenna terminal disturbance voltage, Quasi-peak detection: ±2.0 ㏈
The measurement uncertainty describes the overall uncertainty of the given
measured value during the operation of the EUT in the above-mentioned way.