Read Harman Kardon AVR 270 (serv.man6) EMC - CB Certificate online
Reference No. : 54121209A Page 14/43
◀ Anam EMC Test Laboratory ▶
8.5. Test protocols
Date: September 3, 2012
The equipment does comply with the requirements. Operating condition: The
EUT continuously operated with audio frequency of 1,000 ㎐ color bar being
supplied from the Oscillator or test CD. An absorbing clamp was placed
around all leads. At each mode, the maximum value at each testing frequency
and each output lead was registered and attached as follows.
Test Lead
Freq.
(㎒)
Limit(㏈㎺) Result(㏈㎺)
QP AV QP AV
PHONES
122.88
48.5 38.5 25.9 23.7
FRONT HDMI
30.40
45.0 35.0 23.2 16.4
ZONE2 OUT
221.20
52.1
42.1
* *
REC OUT
221.20
52.1
42.1
* *
ANALOG 1
221.20
52.1
42.1
* *
ANALOG 2
221.20
52.1
42.1
* *
PREOUT
221.20
52.1
42.1
* *
TRIGGER OUT
221.20
52.1
42.1
* *
IR IN/OUT
221.20
52.1
42.1
* *
COAXIAL
221.20
52.1
42.1
* *
COMPOSITE
221.20
52.1
42.1
* *
COMPONENT
221.20
52.1
42.1
* *
HDMI IN/OUT
30.40
45.0 35.0 24.5 18.6
SPEAKER
30.40 45.0 35.0
*
*
AC POWER CORD
122.88
48.5 38.5 *
*
*: less than 25 ㏈㎺
Limit
according
to
EN55013:2001+A2(2006)
Note:1) The spectrum was checked from 30 to 300 ㎒.
2) The cable (6.0m length) loss is included in a correction factor.
3) Detector function of the measuring instrument:
QP: Quasi-peak, AV: Average
4) QP line: Limit (㏈㎺) = Frequency (㎒) ×0.037 + 43.9
AV line: Limit (㏈㎺) = Frequency (㎒) ×0.037 + 33.9
5) *: Less than 25 ㏈㎺
For the measurement data, see Annex C (15 Copies).