IEC 60065   7ed. (2001) 
 
- Page 2 of 3 - 
 
 
www.nemko.com
 
Report No.  98389 
 
 
13.3 – 13.4 
Clearances and Creepage distances 
Type of  
Insulation 
Position/ 
Location 
Position/ 
Location 
Operating 
Voltage (V) 
Clearance 
13.3.2 
Creepage dist 
13.4 
Comm.
Up 
Urms
Req. 
Measu.
Req. 
Measu. 
Basic Live  Neutral 
326V 
230V 
2,0mm 3,6mm 
2,5mm 
3,6mm 
1) 
Basic Live  Neutral 
326V 
230V 
2,0mm 3,6mm 
2,5mm 
3,6mm 
2) 
Reinforce Primary  Chassis  326V  230V 4,0mm 5,4mm 5,0mm 5,4mm  3) 
Reinforce Primary 
  Chassis  326V  230V 4,0mm 5,5mm 5,0mm 5,5mm  4) 
Reinforce  Primary 
*) Chassis  326V  230V  4,0mm 6,0mm 5,0mm > 
6,0mm
5) 
Reinforce Primary  Secondary 382V 270V 4,0mm 5,7mm 5,6mm 
5,7mm  6) 
Reinforce 
Primary 
Chassis 326V 230V 
4,0mm 7,0mm 5,0mm 7,0mm  7) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
*) 2N force applied 
Comments:  1)  Measured on PCB before mains fuse (F901). 
2)   Measured on TRANS pcb after 6,3A mains fuse between CN91 connected copper traces 
 
(Part of directly connected to the mains). 
3)  Measured on main pcb from pri. trace to metal chassis connenected sec. trace. 
4)  Measured between pri. trace for socket-outlet and near metal chassis (back cover). 
5)  Measured between primary solder pin and embossed metal chassis (bottom). 
6)  Measured on main pcb from pri. trace to near secondary trace. 
7)  Measured between primary part of Switch and near metal chassis (back cover). 
 
 
 
 
 
 
Page of 59