AVR 240 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 12

Read Harman Kardon AVR 240 (serv.man13) EMC - CB Certificate online

 
 
- Page 7 of 33 - 
 
 
www.nemko.com
 
Report No.  65654 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
No temperatures measured 
during heating test and fault 
condition tests require this test 
(7.2) to be performed. 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
Considered 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
Operation “By hand”  
not possible 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
No hygroscopic materials 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
No cover removable by hand 
8.5 
Class I equipment 
Class II equipment
 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 
 
Resistors bridging basic insulation complying with 
14.2.1 a) 
 
8.6 
Class II equipment and Class II constructions 
within Class I equipment 
Class II apparatus. 
 
Reinforced or double insulation between 
hazardous live parts and accessible parts 
Double/Reinforced insulation 
complies with requirements 
specified in clause 10 and 13. 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
The apparatus have isolating 
transformers. 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
No such capacitors. 
 
Reinforced or double insulation being bridged with 
2 capacitors in series complying with 14.2.1 a) 
No such capacitors. 
 
Reinforced or double insulation being bridged with 
a single capacitor complying with 14.2.1 b) 
No such capacitors. 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
No such components 
TRF No:  IEC/EN 60065F 
Page of 49
Display