AVR 171 (serv.man5) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 20

Read Harman Kardon AVR 171 (serv.man5) EMC - CB Certificate online

Page 12 of 52 
Report No.: 232174 
 
IEC 60065 
Clause Requirement 
Test 
Result 
Verdict 
 
TRF No. IEC60065K 
 
 
c) Instructions for permanently connected equipment  Not permanently connected 
equipment 
N/A 
 
Marking, signal lamps or similar for completely 
disconnection from the mains  
Information provided in user 
manual. 
 
6 Hazardous 
radiation 
 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h)  
No ionizing radiation 
N/A 
 
Ionizing radiation under fault condition  
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1:2007
 ................................................................................... :
No laser radiation 
N/A 
 
Emission limits under fault conditions  ..................... :  
N/A 
 
7 
Heating under normal operating conditions 
 
7.1 
Temperature rises not exceeding specified values; 
fuse links and other protective devices defeated  
No fuse links operate during 
normal operating operation. 
(see appended table 7.1) 
7.1.1 
Temperature rise of accessible parts  
(see appended table 7.1) 
7.1.2 
Temperature rise of parts providing electrical 
insulation  
(see appended table 7.1) 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier  
(see appended table 7.1) 
7.1.4 
Temperature rise of windings  
(see appended table 7.1) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table 7.1) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
C  
Appliance inlet is certified by  
IEC/EN 60320-1. 
 
Bobbins for transformer/ Line 
filter (base) are made of 
Phenolic. 
 
See appended Table 7.2 for 
AC connector (wafer) CN90 
 
Constructional requirements with regard to the protection against electric 
shock 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare  
Considered 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc.  
Operation ”By hand” not 
possible 
N/A 