AVR 170 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 80

Read Harman Kardon AVR 170 EMC - CB Certificate online

 
Page 15 of 15 
Report No.: 209462 
 
 
ATTACHMENT 3 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
       
TRF No. IEC60065K 
J.2 
NO: After Table J.1 the following is added: 
In Norway, due to the IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230 V in case of a single earth fault. 
Justification: Based on a use in Norway of an IT 
power distribution system where the neutral is not 
provided. 
Noted. 
N/A 
 
ZC 
ANNEX ZC TO EN 60065, A-DEVIATIONS (EN) 
 
5.1 
 
IT: Additional markings on the outside of the TV 
receiver in Italian language 
Not CRT TV set. 
N/A 
 
IT:User instructions in Italian language including a 
conformity declaration 
 
N/A 
 
IT: Certification number on the back cover 
 
N/A 
6.1 
 
DE: The following requirement applies: 
For the operation of any cathode ray tube intended 
for the display of visual images operating at an 
acceleration voltage exceeding 40 kV, authorization 
is required, or application of type approval 
(Bauartzulassung) and marking. 
Justification: German ministerial decree against 
ionizing radiation (Röntgenverordnung), in force 
since 2002-07-01, implementing the European 
Directive 96/29/EURATOM.  
NOTE Contact address: 
Physikalisch-Technische Bundesanstalt, 
Bundesallee 100, D-38116 Braunschweig, Tel.: 
Int+49-531-592-6320, Internet: http://www.ptb.de 
No CRT used in the 
equipment. 
N/A 
14 
 
SE: Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed. 
Justification: Ordinance (1990:944) on Prohibition 
in Connection with handling. Importation and 
exportation of Chemical Products (Certain Cases) 
No such switches 
N/A 
 
 
Page of 85