Read Harman Kardon AVR 170 EMC - CB Certificate online
Page 11 of 15
Report No.: 209462
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
5.3
(A2:2010)
(A2:2010)
Finland, Norway and Sweden
To the end of the subclause the following is added:
To the end of the subclause the following is added:
CLASS I
apparatus which is intended for connection
to the building installation wiring
via a plug or an appliance coupler, or both and in
addition is intended for connection
to other apparatus or a network shall, if safety
relies on connection to protective earth
or if surge suppressors are connected between the
network
via a plug or an appliance coupler, or both and in
addition is intended for connection
to other apparatus or a network shall, if safety
relies on connection to protective earth
or if surge suppressors are connected between the
network
TERMINALS
and
ACCESSIBLE
parts, have a marking stating that the
apparatus must be connected to an
earthed
earthed
MAINS
socket-outlet.
The marking text in the applicable countries shall
be as follows:
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat
uttag”
be as follows:
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat
uttag”
Class II apparatus.
N/A
5.4
(A11:2008
)
(A11:2008
)
Finland, Norway and Sweden
To the end of 5.4 the following is added:
CLASS I apparatus which is intended for
connection to the building installation wiring via a
plug or an appliance coupler, or both and in
addition is intended for connection to other
apparatus or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
TERMINALS and ACCESSIBLE parts, have a
marking stating that the apparatus must be
connected to an MAINS socket-outlet with
protective earth.
The marking text in the applicable countries shall
be as follows:
In Finland: “Laite on liitettävä
suojamaadoituskoskettimilla varustettuun
pistorasiaan”
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: "Apparaten skall anslutas till jordat
uttag"
To the end of 5.4 the following is added:
CLASS I apparatus which is intended for
connection to the building installation wiring via a
plug or an appliance coupler, or both and in
addition is intended for connection to other
apparatus or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
TERMINALS and ACCESSIBLE parts, have a
marking stating that the apparatus must be
connected to an MAINS socket-outlet with
protective earth.
The marking text in the applicable countries shall
be as follows:
In Finland: “Laite on liitettävä
suojamaadoituskoskettimilla varustettuun
pistorasiaan”
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: "Apparaten skall anslutas till jordat
uttag"
Class II apparatus.
N/A