Read Harman Kardon AVR 147 (serv.man3) EMC - CB Certificate online
Reference No. : 54120707A Page 13
◀ Anam EMC Test Laboratory ▶
Antenna terminal disturbance voltage due to the local oscillator.
Channel Harmonic
Measured
freq. (㎒)
Limit(㏈㎶)
Disturbance
value(㏈㎶)
1
110.8
54.0
39.2
2
221.6
50.0
32.1
3
332.4
50.0
31.1
4
443.2
52.0
*
100.1 5 554.0
52.0 31.1
6
664.8
52.0
30.2
7
775.6
52.0
36.5
8
886.4
52.0
*
9
997.2
52.0
*
1
116.8
54.0
40.1
2
233.6
50.0
32.3
3
350.4
52.0
32.1
4
467.2
52.0
*
106.1 5 584.0
52.0 32.3
6
700.8
52.0
31.7
7
817.6
52.0
37.7
8
934.4
52.0
*
1
118.7
54.0
39.7
2
237.4
50.0
32.5
3
356.1
52.0
32.4
108.0 4 474.8
52.0 *
5
593.5
52.0
32.1
6
712.2
52.0
30.8
7
830.9
52.0
38.9
8
949.6
52.0
*
OTHERS
Antenna terminal disturbance voltage due to other source than local oscillator.
Channel Harmonic
Measured
freq. (㎒)
Limit(㏈㎶)
Disturbance
value(㏈㎶)
98.0 / 46.0 *
*: less than 30 ㏈㎶
Limit according to EN55013:2001