Reference No. : 54120707A                                                                                                                        Page 13
 
◀  Anam EMC Test Laboratory  ▶
 
 
 
Antenna terminal disturbance voltage due to the local oscillator. 
Channel Harmonic 
Measured 
freq. (㎒) 
Limit(㏈㎶) 
Disturbance 
value(㏈㎶) 
 1 
110.8 
54.0 
39.2 
 2 
221.6 
50.0 
32.1 
 3 
332.4 
50.0 
31.1 
 4 
443.2 
52.0 
100.1 5 554.0 
52.0 31.1 
 6 
664.8 
52.0 
30.2 
 7 
775.6 
52.0 
36.5 
 8 
886.4 
52.0 
 9 
997.2 
52.0 
 1 
116.8 
54.0 
40.1 
 2 
233.6 
50.0 
32.3 
 3 
350.4 
52.0 
32.1 
 4 
467.2 
52.0 
106.1 5 584.0 
52.0 32.3 
 6 
700.8 
52.0 
31.7 
 7 
817.6 
52.0 
37.7 
 8 
934.4 
52.0 
 1 
118.7 
54.0 
39.7 
 2 
237.4 
50.0 
32.5 
 3 
356.1 
52.0 
32.4 
108.0 4 474.8 
52.0  * 
 5 
593.5 
52.0 
32.1 
 6 
712.2 
52.0 
30.8 
 7 
830.9 
52.0 
38.9 
 8 
949.6 
52.0 
 
 
OTHERS 
Antenna terminal disturbance voltage due to other source than local oscillator. 
Channel Harmonic 
Measured 
freq. (㎒) 
Limit(㏈㎶) 
Disturbance 
value(㏈㎶) 
98.0   / 46.0 * 
 
*: less than 30 ㏈㎶  
 
                                            Limit according to EN55013:2001 