Read Harman Kardon AVR 140 (serv.man4) EMC - CB Certificate online
- Page 6 of 7 -
www.nemko.com
Report No. 65586
13.3 - 13.4
Clearances and Creepage distances
P
Type of
Insulation
Position/
Location
Location
Position/
Location
Location
Working
Voltage
Clearance
13.3.2
Creepage dist.
13.4
Comm.
1 2
Up
Urms
Req.
Measu.
Req.
Measu.
Basic Live Neutral 326V
230V
2,0mm
4,0mm 2,5mm
4,0mm
1)
Reinforce Primary
Chassis
326V 230V 4,0mm 8,0mm 5,0mm >
8,0mm 2)
Reinforce Primary
C708
*)
377V 266V 4,0mm 7,8mm 5,6mm >
7,8mm
3)
Reinforce Primary
Chassis
326V 230V 4,0mm 7,3mm 5,0mm >
7,3mm 4)
Reinforce Primary
Chassis
326V 230V 4,0mm 6,8mm 5,0mm 6,8mm 5)
Reinforce Primary
Secondary 377V 266V 4,0mm 6,0mm 5,6mm 6,0mm 6)
*) 2N force applied
Note: U in Volt, Clearances/Creepage Distances in mm, Comm. = Comment
Comments:
1) Measured on PCB before mains fuse (F907).
2) Measured between primary pcb trace for socket-outlet and near metal chassis (back cover).
3) Measured between socket outlet terminal and near C708 secondary E. capacitor.
4) Measured between main pcb primary solder pin and metal bottom chassis.
5) Measured on main pcb from pri. pcb trace to metal chassis connected sec. pcb trace.
6) Measured on main pcb from pri. pcb trace to near secondary pcb trace.
2) Measured between primary pcb trace for socket-outlet and near metal chassis (back cover).
3) Measured between socket outlet terminal and near C708 secondary E. capacitor.
4) Measured between main pcb primary solder pin and metal bottom chassis.
5) Measured on main pcb from pri. pcb trace to metal chassis connected sec. pcb trace.
6) Measured on main pcb from pri. pcb trace to near secondary pcb trace.