AVR 140 (serv.man4) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 47

Read Harman Kardon AVR 140 (serv.man4) EMC - CB Certificate online

 
 
- Page 6 of 7 - 
 
 
www.nemko.com
 
Report No.  65586 
 
 
13.3 - 13.4
 
Clearances and Creepage distances
 P 
Type of 
Insulation 
Position/ 
Location 
Position/ 
Location 
Working  
Voltage 
Clearance 
13.3.2 
Creepage dist. 
13.4
 
Comm. 
 1  2 
Up 
Urms
Req. 
Measu.
Req. 
Measu. 
 
Basic Live  Neutral  326V 
230V 
2,0mm 
4,0mm 2,5mm 
4,0mm 
1) 
Reinforce Primary 
Chassis 
326V  230V  4,0mm  8,0mm 5,0mm > 
8,0mm 2) 
Reinforce Primary 
C708 
*) 
377V 266V 4,0mm 7,8mm 5,6mm > 
7,8mm 
3) 
Reinforce Primary 
Chassis 
326V  230V  4,0mm  7,3mm 5,0mm > 
7,3mm 4) 
Reinforce Primary 
Chassis 
326V  230V  4,0mm  6,8mm 5,0mm 6,8mm  5) 
Reinforce Primary 
Secondary  377V 266V 4,0mm 6,0mm 5,6mm 6,0mm  6) 
 
 
 
 
 
 
 
 
 
 
*) 2N force applied 
Note: U in Volt, Clearances/Creepage Distances in mm, Comm. = Comment 
Comments: 
1)  Measured on PCB before mains fuse (F907). 
2)  Measured between primary pcb trace for socket-outlet and near metal chassis (back cover).
3)  Measured between socket outlet terminal and near C708 secondary E. capacitor. 
4)  Measured between main pcb primary solder pin and metal bottom chassis. 
5)  Measured on main pcb from pri. pcb trace to metal chassis connected sec. pcb trace. 
6)  Measured on main pcb from pri. pcb trace to near secondary pcb trace. 
 
 
 
 
Page of 48
Display

Click on the first or last page to see other AVR 140 (serv.man4) service manuals if exist.