Read Harman Kardon AVR 140 (serv.man4) EMC - CB Certificate online
- Page 3 of 7 -
www.nemko.com
Report No. 65586
11
FAULT CONDITIONS TESTS-continued
P
Comp.
No.
No.
Location Fault
Test V
Test
time
time
Fuse
No.
No.
Current
through
fuse
through
fuse
Temperature/Results
C923
-
S-c
253
30 min
F907
1,03 A
Output signal off immediately.
Input current stabilised at 0,55A.
No component damaged.
No hazard.
Input current stabilised at 0,55A.
No component damaged.
No hazard.
D915
A - C
S-c
253
30 min
F907
1,57 A
Output signal dropped to 4V.
Input current stabilised at 1,10A.
R104 opened and D916 damaged.
No hazard.
Input current stabilised at 1,10A.
R104 opened and D916 damaged.
No hazard.
C931
-
S-c
253
30 min
F907
0,90 A
Output signal off immediately.
Input current stabilised at 0,47A.
R104, R105 opened and
D915 damaged. No hazard.
Input current stabilised at 0,47A.
R104, R105 opened and
D915 damaged. No hazard.
C909 - S-c 207 10
min
F907
F905
F906
F905
F906
-
Surround, Center channels signal
output off immediately.
Input current stabilised at 0,81 A.
F905, F906 opened.
No hazard.
output off immediately.
Input current stabilised at 0,81 A.
F905, F906 opened.
No hazard.
C909 - S-c 253 10
min
F907
F905
F906
F905
F906
-
Surround, Center channels signal
output off immediately.
Input current stabilised at 0,90 A.
F905, F906 opened.
No hazard.
output off immediately.
Input current stabilised at 0,90 A.
F905, F906 opened.
No hazard.
C916 - S-c 253 10
min
F907
F903
F904
F903
F904
-
Front, S/B channels signal output
off immediately.
Input current stabilised at 0,86A.
F903, F904 opened.
No hazard.
off immediately.
Input current stabilised at 0,86A.
F903, F904 opened.
No hazard.
Q803
C - E
S-c
207
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
F905, F906 opened.
No hazard.
Input current stabilised at 0,01A.
F905, F906 opened.
No hazard.
Q803
C - E
S-c
253
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
F905, F906 opened.
Q804 shorted.
No hazard.
Input current stabilised at 0,01A.
F905, F906 opened.
Q804 shorted.
No hazard.
Q803
B - C
S-c
253
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection