Read Harman Kardon AVR 140 (serv.man4) EMC - CB Certificate online
- Page 13 of 32 -
www.nemko.com
Report No. 65586
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
13
CLEARANCE AND CREEPAGE DISTANCES
13.1
Clearances in accordance with 13.3
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition.
P
Creepage distances in accordance with 13.4
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition.
P
13.2
Determination of operating voltage
Conventional transformer
used.
Upper rated supply voltage
applied in determining the
operating voltage.
used.
Upper rated supply voltage
applied in determining the
operating voltage.
P
13.3 Clearances
2N for internal parts and 30N
for enclosures are considered
when determining clearances.
for enclosures are considered
when determining clearances.
P
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
No hazardous secondary
voltages
voltages
N
13.4 Creepage
distances
CTI > 100
See attachment, Table to
EN/IEC 60065 7
See attachment, Table to
EN/IEC 60065 7
th
edition
P
Creepage distances greater than table 11 minima
Not applicable
N
13.5 Printed
boards
N
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N
13.5.2
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
with IEC 60664-3 (basic insulation only)
No type B coated PWB
N
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
Jointed insulation not applied
N
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
No enclosed, enveloped or
hermetically sealed parts
hermetically sealed parts
N
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
No parts filled with insulating
compound
compound
N
TRF No: IEC/EN 60065F
Click on the first or last page to see other AVR 140 (serv.man4) service manuals if exist.