Read Harman Kardon AVR 140 (serv.man4) EMC - CB Certificate online
- Page 8 of 32 -
www.nemko.com
Report No. 65586
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
No such capacitors.
N
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
No such capacitors.
N
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
No such components
N
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
No parts at 35V to 71V (peak)
a.c. or 60V to 120V d.c.
a.c. or 60V to 120V d.c.
N
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
No parts at 35-71V(peak) a.c. or
60-120V d.c.
60-120V d.c.
N
Separation by Class II isolating transformer
Isolating transformer according to
14.3.2. (Class II)
14.3.2. (Class II)
P
Separation by Class I transformer
N
Separation by earthed conductive part
N
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N
Reinforced
insulation > 0,4 mm (mm) .................... :
Transformer bobbin,
See appended table and
attachment, Table to
EN/IEC 60065 7
See appended table and
attachment, Table to
EN/IEC 60065 7
th
edition
P
Thin sheet insulation
No thin sheet insulation
N
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Double insulated
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
Single insulation but safely
anchored
anchored
P
TRF No: IEC/EN 60065F