Read Harman Kardon AVR 135 (serv.man2) EMC - CB Certificate online
Reference No. : 54120503A Page 7
◀ Anam EMC Test Laboratory ▶
5.4. Test instrument
Equipment
Manufacturer
Type No.
Serial No.
Test site
Shielded room
-
-
Spectrum monitor
R & S
EZM
862064/004
R & S
ESH3
894718/017
Measurement
Receiver R & S
Receiver R & S
ESCS30
847124/017
R & S
ESH3-Z5
844249/020
Artificial mains
Network EMCO 3825/2 90101718
Signal Generator
Network EMCO 3825/2 90101718
Signal Generator
Anritsu
MG3632A
MT79870
R. C. Oscillator
Kenwood
AG-203A
3090241
/
* R & S: Rohde & Schwarz
5.5. Test protocol
Date: February 23, 2005
Grounded at the Signal GND Terminal on the Rear Enclosure.
An overview sweep performed with peak detector is included in the test
report as Annex A.
report as Annex A.
Quasi-peak (㏈㎶) Average
(㏈㎶)
Disturbance value
Disturbance value
Mode
Freq.
(㎒)
Limit
Line 1
Line 2
Limit
Line 1
Line 2
Tuner 4.43 56 37.9 39.1 46.0 37.1 37.3
13.30 60 29.0 32.8 50 26.6 29.9
Ungrounded at the Signal GND Terminal on the Rear Enclosure.
An overview sweep performed with peak detector is included in the test
report as Annex A
report as Annex A
Quasi-peak (㏈㎶) Average
(㏈㎶)
Disturbance value
Disturbance value
Mode
Freq.
(㎒)
Limit
Line 1
Line 2
Limit
Line 1
Line 2
Tuner
4.43 56 32.4 34.1 46 31.2 32.0
10.00 60 26.1 26.0 50 19.3 19.0
13.30 60 25.6 20.1 50 23.0 19.2
13.30 60 25.6 20.1 50 23.0 19.2
VID3
4.43 56 36.2 37.1 46 35.3 35.3
26.61 60 27.8 26.5 50 26.8 26.5
The equipment does comply with the requirements.
For the measurement data, see Annex A (6 Copies).