Read Harman Kardon AURA (serv.man3) EMC - CB Certificate online
Report No.: EM201300550-9 Application No.: ZJ00032797 Page 57 of 69
5.8 VOLTAGE DIP & VOLTAGE INTERRUPTIONS
5.8.1 TEST SPECIFICATION
Basic Standard
EN 61000-4-11:2004
Test duration time
Voltage dips:
30 during 25 periods,
Meets the requirements of Performance Criterion C
Meets the requirements of Performance Criterion C
Voltage interruption:
100% during 0.5 cycles,
100% during 1 cycles,
100% during 1 cycles,
Meets the requirements of Performance Criterion B
100% during 250 cycles,
Meets the requirements of Performance Criterion C
Interval between event
10s for each dips at each test angle
Phase Angle
0°
Test cycle
3
5.8.2 TEST PROCEDURE
a) The EUT and test generator were setup as shown on Section
b) The interruptions is introduced at selected phase angles with specified duration.
c) Record any degradation of performance.
b) The interruptions is introduced at selected phase angles with specified duration.
c) Record any degradation of performance.
5.8.3 TEST SETUP
Click on the first or last page to see other AURA (serv.man3) service manuals if exist.