Read Sony KV-32HS510 Service Manual online
— 16 —
KV-32HS510/34DRC510/34HS510/36HS510/38DRC510
11. LLMB (Left Lower Middle BOW)
B R
12. CADJ Fix 29
2-4. FOCUS ADJUSTMENT
Confirm neck assembly Z axis position. (See Figure 1)
1. Input a dot signal.
2. Set Video Mode to STANDARD.
3. Adjust focus VR clockwise (DE-Focus) to confirm that the dot’s shape
1. Input a dot signal.
2. Set Video Mode to STANDARD.
3. Adjust focus VR clockwise (DE-Focus) to confirm that the dot’s shape
is centered. (Figure 2 & 3) Confirm neck assembly rotation by W Board
position. W Board should be level ±1º. Adjust as necessary to balance
dot shape along center horizontal line, then refocus.
4. Input a HD monoscope signal.
5. Confirm center focus with focus VR.
5. Confirm center focus with focus VR.
Figure 1
FOCUS
Screen (G2)
DOT SHAPE:
NOTE: Changing neck assembly position will affect corner convergence.
2-4.1. DYNAMIC FOCUS/DYNAMIC QUADRA-
POLE DATA
Normally, no adjustments are necessary for these systems. If for some
reason the data is lost, use the following data:
Write the data from any non-vertically compressed mode, then use the
CPY1 function (CXA2170D-4 Item 6) to copy the data to the vertical
compressed modes. V-compressed data is identical to non-v-compressed
data. Service personnel with a trained eye can adjust the DF or DQP
registers to adjust DF phase (Item 7) or DQP phase (Item 8), respectively,
to balance left and right focus. Refrain from adjusting more than 5 steps
from table data below. Further adjustment indicates a circuit problem
-- troubleshoot to cause. Be sure that Neck Assembly is in the proper
location
(See Section 2-4 Figure 1 - before changing DF/DQP data or
troubleshooting circuit when DF/DQP is suspect.)
Figure 2
Figure 3
Click on the first or last page to see other KV-32HS510 service manuals if exist.