DCR-TRV250 (serv.man4) - Sony Movie Service Manual (repair manual). Page 8

Read Sony DCR-TRV250 (serv.man4) Service Manual online

DCR-TRV250
6-6
Fig. 6-1-3
1-1-2. Preparations
Note 1:
For details of how remove the cabinet and boards, refer
to “2. DISASSEMBLY”.
Note 2:
When performing only the adjustments, the lens block
and boards need not be disassembled.
1) Connect the equipment for adjustments according to Fig. 6-1-
5.
2) Connect the adjustment remote commander to VC-305 board
CN1011 via I/F unit for LANC control (J-6082-521-A) and
CPC jig connector (J-6082-539-A). (Fig. 6-1-4)
The “Jig Modification” is necessary for connecting the adjust-
ment remote commander to this set.
Modify the jig by referring to page 6-5.
To operate the adjustment remote commander, connect the AC
power adaptor to the DC IN jack of I/F unit for LANC control,
or connect the L series Info-LITHIUM battery to the battery
terminal of I/F unit for LANC control.
3) The front panel block (SI-035 board,  video light, microphone
unit) need not be assembled except during the steadyshot op-
eration check.
Note 3:
As removing the cabinet (R) (removing the VC-305 board
CN1007) means removing the lithium 3V power supply
(CF-3000 block BT001), data such as date, time, user-
set menus will be lost. After completing adjustments,
reset these data. If the cabinet (R) has been removed, the
self-diagnosis data, data on history of use (total drum
rotation time, etc. ) will be lost. Before removing, note
down the self-diagnosis data (data of page: 7, address:
B0 to C6) and data on history use (data of page: 7, ad-
dress: A7 to A9 and C8 to CF). (Refer to “SELF-DIAG-
NOSIS FUNCTION” for the self-diagnosis data, and to
“6-4. Service Mode” for the data on the history use)
Note 4:
Setting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press
the PAUSE button of the adjustment remote com-
mander.
The above procedure will enable the camera power
to be turned on with the power switch (SS-3000 block)
removed. After completing adjustments, be sure to
exit the “Forced Camera Power ON Mode”.
Note 5:
Exiting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press
the PAUSE button of the adjustment remote com-
mander.
3) Select page: 0, address: 01, and set data: 00.
Fig. 6-1-4
Front of the lens
1.5 m
Pattern box
CN1011
16
1
Conductor 
side
Page of 67
Display

Click on the first or last page to see other DCR-TRV250 (serv.man4) service manuals if exist.