Adhesive bond (B-10): J-6082-612-A
1.  Install the 2nd lens adjustment washer to the unit.
2  Set the index mark and the circular hole to 5 o'clock position in infinity end state, then attach the 2nd group assy to the unit 
and fix them with three screws.
3.  Apply adhesive bond (B-10) to the hole of 2nd group assy in 3 locations, set the index mark and cut portion to the 5:30 posi-
tion, then attach the 2nd lens ornament ring to the unit.
Unit
Index mark
Index mark
Index mark
2nd Group Assy
2nd Lens Ornament Ring
2nd Lens Adjustment Washer
2nd Lens Ornament Ring 
(Viewed from the objective lens side)
Cut portion
(The 5:30 direction 
at infinity end)
2nd Group Assy 
(Viewed from the objective lens side)
Circular Hole
(The 5 o'clock position in infinity end state)
Apply the adhesive
bond (B-10)
HELP04
Adhesive bond (B-10): J-6082-612-A
How to remove the mount block
1.  Remove four screws.
2.  Set the unit to the TELE end, then remove the mount block with detaching the preset lever from the aperture lever.
Mount Block
Unit
Preset Lever
Aperture Lever
How to install the mount block
1.  Set the unit to the WIDE end, then install the mount block while attaching the preset lever to the aperture lever.
2.  Fix the mount block with four screws.
3.  After finishing the aperture diameter adjustment, tighten the function lever with two screws then apply adhesive bond (B-10) 
to the heads of two screws.
Aperture Lever
Mount Block
Preset Lever
Preset Lever
Apply the adhesive
bond (B-10)