Read Sharp PZ-50HV2E (serv.man9) Service Manual online
37
PZ-50HV2, PZ-50HV2E
PZ-50HV2U
PZ-50HV2U
When a module microcomputer failed in communication with a panel
microcomputer, this NG occurs.
Shut down after OSD display for 30 seconds from the NG detection.
microcomputer, this NG occurs.
Shut down after OSD display for 30 seconds from the NG detection.
Abnormality to expect
Open / Short of communication line in the Assy
Open / Short of communication line in the Assy
1
Panel microcomputer NG
When a module microcomputer failed in communication with outside
EEPROM or EXPANDER, this NG occurs.
Shut down after OSD display for 30 seconds from the NG detection.
* However, this communication NG may occur in the standby state.
EEPROM or EXPANDER, this NG occurs.
Shut down after OSD display for 30 seconds from the NG detection.
* However, this communication NG may occur in the standby state.
Abnormality to expect
• Open / Short of communication line in the DIGITAL VIDEO, MR INTERFACE
• Open / Short of communication line in the DIGITAL VIDEO, MR INTERFACE
and AUDIO Assys
• Breaking of wire of the following points is thought about.
DIGITAL VIDEO Assy (D1)
↔
SW POWER SUPPLY Module (P2)
DIGITAL VIDEO Assy (D3)
↔
MR INTERFACE Assy (R3)
MR INTERFACE Assy (R23)
↔
AUDIO Assy (A24)
System Cable
2
DIGITAL-IIC communication NG
When it becomes the dew drop state in this unit, this NG occurs.
After the dew drop detection, shut down immediately.
After the dew drop detection, shut down immediately.
Abnormality to expect for dew drop
Disconnect a connector CN2002 between Dew drop sensor and Y DRIVE Assy.
Disconnect a connector CN2002 between Dew drop sensor and Y DRIVE Assy.
3
Dew drop detection
When temperature of this unit became abnormally high, this NG occurs.
Shut down after OSD display from the NG detection for 30 seconds.
Note: When temperature fell down during indication, return to the normal operation.
Shut down after OSD display from the NG detection for 30 seconds.
Note: When temperature fell down during indication, return to the normal operation.
Abnormality to expect when it occurs in the environment that is not
high-temperature
• Disconnect a connector between DIGITAL VIDEO Assy (D18) and
high-temperature
• Disconnect a connector between DIGITAL VIDEO Assy (D18) and
temperature sensor 1 (TE1).
Shut down temperature of each temperature sensor
Sensor Temp 78
Sensor Temp 78
4
Temperature abnormality
Reference
Shut down diagnosis
1
2
3
4
5
6
7
8
9
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
11
12
13
14
15
16
17
18
CENTE
1 / 1 3
R Ve r s
OSD Ve r s i o n
CV I C Ve r s i o n
CV I C Ve r s i o n
TTXP Ve r s i o n
i on
MON I TOR Ve r s i on
Mod e l S l e
e
c t
i n
Ma
Mod e l S l e
e
c t AV
Mod e l S l e
e
c t
Ce n t e r
c u
A
t i me
MON I TOR
RESET
RESET
OFF
RESET
OFF
OFF
+
0
0
4
4
2 8
F 6 9 1 1 0
TTX
R
P G
W2 0 0 /
1 0 9
0
0 0
9 :
1 2
/
X2 0 0 /
1 0 9
0
0 7
9 :
1 2
/
V2 0
0 6 1
0 /
1 0 9
0
1 0
9 :
1 2
/
MR O D
S
2
0
1 0
9
A
/
/
0 1
0
MR M I
A N
0 0
2
1
E
- 0 5
- 0 0
PANEL Ve r s i on
FLASH Ve r s i on
FLASH Ve r s i on
MON I TOR Mo de l
Mon i t o r Ac u t i me
4 7
H
4 2 M
H
4 1 M
1 6
0 1
Pu l s e Ac u t i me
1 6 4
Se n s o r e Temp
0
2 5 H
9 /
/
NP
I
U
S
1
G
I
No
T
E06
E06
E04
Click on the first or last page to see other PZ-50HV2E (serv.man9) service manuals if exist.