AR-C270 (serv.man13). (Section 8) Simulations - Sharp Copying Equipment Service Manual (repair manual). Page 7

Read Sharp AR-C270 (serv.man13) Service Manual online

Code
Function (Purpose)
Purpose
Section
Item
Main
Sub
43
1
Used to set the fusing temperature in each
operation mode.
Setting
Fixing (Fusing)
Operation
7
Used to adjust the fusing oil supply amount.
(Adjustment of oil motor ON time and oil
motor ON interval)
Adjustment
Fixing (Fusing)
Operation
44
1
Used to set enable/disable of correction
operations in the image forming (process)
section.
Setting
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Operation
2
Used to check the operation of the
temperature sensor and the humidity sensor
for correction of the image process section.
(The sensor detection level can be
monitored.)
Operation test/check
Operation
4
Used to set the target image (reference)
density level in correction (process
correction) operations in the image forming
section.
Setting
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Picture quality
Density
5
Used to set the correction start developing
bias voltage in correction (process
correction) operations in the image forming
section.
Setting
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Developer/
Toner Hopper
Operation
6
Used to forcibly execute the image forming
section correction (process correction).
Operation test/check
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Operation
9
Used to check the data on the image forming
section correction (process correction)
(corrected main charger grid voltage, the
developing bias voltage, the laser power, etc,
in each print mode). (This simulation allows
to check if the correction operation is
performed normally.)
Operation data
output/Check
(Display/Print)
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Data
Operation data
(Machine
condition)
12
Used to check the toner image patch density
data in the image forming section correction
(process correction). This simulation allows
to check if the correction operation is
performed normally.)
Operation data
output/Check
(Display/Print)
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Data
Operation data
(Machine
condition)
13
Used to adjust the image density sensor (for
color) sensitivity (gain).
Adjustment
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Copy
14
Used to monitor the output level of the fusing
temperature sensor, the machine
temperature sensor, and the humidity sensor.
Operation data
output/Check
(Display/Print)
Others
16
Used to check the toner concentration
correction result. (This simulation allows to
check if correction is executed properly or
not.)
Operation data
output/Check
(Display/Print)
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Developer/
Toner Hopper
Data
Operation data
(Machine
condition)
20
Used to adjust the phase of OPC drum
deflection. (Used to adjust deflection phases
of four OPC drums.) (Old)
Adjustment
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Photo
conductor
Operation
21
Used to store color balance adjustment data.
(Half tone image correction initial setting)
(After execution of color balance adjustment
with SIM 46-21, this simulation must be
executed.)
Setting
Picture quality
22
Used to check each color toner patch image
density UITU in half tone image forming
section correction (process correction). (This
simulation allows to check if correction
operation is performed normally.)
Operation data
output/Check
(Display/Print)
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Data
Operation data
(Machine
condition)
23
Used to adjust the image density sensor
position (main scan direction). (The position
is adjusted when toner patch is formed.)
Adjustment
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Copy
24
Used to check the half tone correction result.
(This simulation allows to check if correction
is executed properly or not.)
Operation data
output/Check
(Display/Print)
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Data
Operation data
(Machine
condition)
25
Used to check the half tone correction result.
(This simulation allows to check if correction
is executed properly or not.)
Operation data
output/Check
(Display/Print)
Image process
(Photoconductor/
Developing/Transfer/
Cleaning)
Data
Operation data
(Machine
condition)
8 –  7
Page of 34
Display