PULSE (serv.man6) - JBL Audio EMC - CB Certificate (repair manual). Page 14

Read JBL PULSE (serv.man6) EMC - CB Certificate online

 
Page 14 of 51 
Report No. 241619 
 
  
IEC 
60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IEC60950_1C 
 
 
1.7.2 
Safety instructions and marking 
The user’s manual contains 
information for operation, 
installation, servicing, 
transport, storage, technical 
data and battery show in the 
user manual. No other special 
installation instruction 
required as the equipment is 
class III. 
1.7.2.1 General 
Considered. 
 
1.7.2.2 
Disconnect devices 
Class III equipment. 
N/A 
1.7.2.3 Overcurrent 
protective device 
Class III equipment. 
N/A 
1.7.2.4 
IT power distribution systems 
Class III equipment. 
N/A 
1.7.2.5 
Operator access with a tool 
All areas containing hazard(s) 
are inaccessible to the 
operator. 
1.7.2.6 
Ozone 
The equipment does not 
produce Ozone. 
N/A 
1.7.3 
Short duty cycles 
The equipment is intended for 
continuous operation. 
N/A 
1.7.4 
Supply voltage adjustment  ................................... :  No voltage select switch. 
N/A 
 
Methods and means of adjustment; reference to 
installation instructions  ......................................... : 
 
 
1.7.5 
Power outlets on the equipment  .......................... :  No standard power outlet. 
N/A 
1.7.6 
Fuse identification (marking, special fusing 
characteristics, cross-reference)  .......................... : 
Class III equipment. 
N/A 
1.7.7 
Wiring terminals 
Class III equipment. 
 
1.7.7.1 Protective 
earthing 
and bonding terminals  .......... :   
N/A 
1.7.7.2 
Terminals for a.c. mains supply conductors  
 
N/A 
1.7.7.3 
Terminals for d.c. mains supply conductors 
 
N/A 
1.7.8 
Controls and indicators 
Refer below. 
 
1.7.8.1 
Identification, location and marking  ..................... :  The function of controls 
affecting safety is obvious 
without knowledge of 
language etc. 
1.7.8.2 Colours 
  ................................................................ :   
N/A 
1.7.8.3 
Symbols according to IEC 60417 ........................ : 
The functional switch is 
marked with the symbols:       
 " (IEC 60417-1 No. 
5010). 
Page of 118