Read JBL PULSE (serv.man6) EMC - CB Certificate online
Page 13 of 51
Report No. 241619
IEC
60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1C
1.5.9
Surge suppressors
No such component used
N/A
1.5.9.1 General
N/A
1.5.9.2
Protection of VDRs
N/A
1.5.9.3
Bridging of functional insulation by a VDR
N/A
1.5.9.4
Bridging of basic insulation by a VDR
N/A
1.5.9.5
Bridging of supplementary, double or reinforced
insulation by a VDR
insulation by a VDR
N/A
1.6 Power
interface
P
1.6.1
AC power distribution systems
The equipment is regarded as
Class III.
Class III.
N/A
1.6.2 Input
current
(see appended table 1.6.2)
P
1.6.3
Voltage limit of hand-held equipment
The equipment is not hand-
held.
held.
N/A
1.6.4
Neutral conductor
The equipment is regarded as
Class III.
Class III.
N/A
1.7
Marking and instructions
P
1.7.1
Power rating and identification markings
The required marking is
located on the outside surface
of the equipment.
located on the outside surface
of the equipment.
P
1.7.1.1
Power rating marking
See below
P
Multiple mains supply connections..........................: Class III equipment.
N/A
Rated voltage(s) or voltage range(s) (V) .............. : 5V DC
P
Symbol for nature of supply, for d.c. only .............. : IEC 60417-1, symbol No.
5031, is used.
P
Rated frequency or rated frequency range (Hz) ... : DC supplied.
N/A
Rated current (mA or A) ........................................ : 2.3A
—
1.7.1.2
Identification markings
See below.
P
Manufacturer’s name or trade-mark or identification
mark ...................................................................... :
mark ...................................................................... :
See page 2
P
Model identification or type reference ................... : See page 2
—
Symbol for Class II equipment only ...................... : Class III equipment
N/A
Other markings and symbols ................................ : The additional marking does
not give rise to
misunderstandings.
misunderstandings.