CS - JBL Audio EMC - CB Certificate (repair manual). Page 16

Read JBL CS EMC - CB Certificate online

 
Page 13 of 45 
Report No. 703637 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
14.3.3 
Constructional requirements (complete appended tables or include manufacturers 
constructional insulation descriptions) 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
 P 
14.3.3.2 
Transformers meet the constructional requirements   
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
TT0900101020-E 
Prim. – sec.= >10mm 
150-r4055901-e: 
Prim. – sec.= >8.3mm 
 
Coil formers and partition walls = 0.4 mm 
Thin sheet 
14.3.4.2 Class 
transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
 N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 N/A 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Core not connected to 
accessible parts. 
N/A 
 
Coil formers and partition walls = 0.4 mm 
Thin sheet 
N/A 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
 N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N/A 
14.4 
High voltage components 
 
High-voltage components and assemblies: U > 4 kV 
(peak) separately approved 
 N/A 
 
Component meets category V-1 of IEC 60707 
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 N/A 
14.5 
Protective devices 
 
Protective devices used within their ratings 
 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
 P 
Page of 58