DPR 2005 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 42

Read Harman Kardon DPR 2005 EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 38 of 41 - 
 
 
   
 Order 
No. 
24776
 
 
 
 
FAULT CONDITION TESTS (Continued) 
P
Comp. 
No 
Fault Test 
Point Test 
time 
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
BD202 
S-c 
253 
AC – (+) 
30 min 
F101 
0,23 A 
Output signal off immediately. 
T101 primary winding heated up to
118K and thermal fuse opened 
after 14 min. 
Input current stabilised at 0,20 A. 
Dielectric strength test OK. 
No hazard. 
C218 
S-c 
253 
40 min 
F101 
1,53 A 
T101 primary winding heated up to
120K and thermal fuse opened 
after 21 min. 
Input current stabilised at 0,20 A. 
Dielectric strength test OK. 
No hazard. 
BD201 
S-c 
253 
AC – (+) 
30 min 
F101 
1,52 A 
T101 primary winding heated up to
121K and thermal fuse opened 
after 19 min. 
Input current stabilised at 0,20 A. 
Dielectric strength test OK. 
No hazard. 
C220 
S-c 
253 
40 min 
F101 
0,19 A 
T101 primary winding heated up to
116K and thermal fuse opened 
after 25 min. 
Input current stabilised at 0,20 A. 
Dielectric strength test OK. 
No hazard. 
D206 
S-c 
253 
A - C 
50 min 
F101 
2,10 A 
Unit shut down after 25 min. 
Input current stabilised at 0,20 A. 
D206, T102 damaged and 
C210, C220, C211 vented. 
Dielectric strength test OK. 
No hazard. 
C216 
S-c 
253 
10 min 
F101 
0,20 A 
Unit shut down immediately. 
Input current stabilised at 0,20 A. 
No component damaged. 
No hazard. 
D207 
S-c 
253 
A - C 
10 min 
F101 
2,00 A 
Unit shut down after 4 min. 
Input current stabilised at 0,20 A. 
T102 damaged. 
Dielectric strength test OK. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 
Page of 53
Display