DPR 2005 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 41

Read Harman Kardon DPR 2005 EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 37 of 41 - 
 
 
   
 Order 
No. 
24776
 
 
 
 
FAULT CONDITION TESTS  
P
Ambient temperature  
 25,5 °C 
Rated voltage  
230V~ 
Remarks  
Comp. 
No 
Fault Test 
Point Test 
time 
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
BD101 
S-c 
253 
AC - (+) 
1 sec. 
F101 
F101 opened immediately. 
No hazard. 
BD101 
S-c 
207 
AC - (+) 
1 sec. 
F101 
F101 opened immediately. 
No hazard. 
C106 
S-c 
253 
1 sec. 
F101 
F101 opened immediately. 
No hazard. 
C106 
S-c 
207 
14 sec. 
F101 
3,60 A 
F101 opened After 14 sec. 
C107 damaged. 
No hazard. 
C107 
S-c 
253 
1 sec. 
F101 
F101 opened immediately. 
No hazard. 
C107 
S-c 
207 
17 sec. 
F101 
9,30 A 
F101 opened After 17 sec. 
C106 damaged. 
No hazard. 
Q102 
S-c 
253 
S – D 
1 sec. 
F101 
F101 opened immediately. 
Q103, ZD102 damaged. 
No hazard. 
Q102 
S-c 
253 
D - G 
1 sec. 
F101 
F101 opened immediately. 
Q103, ZD101 damaged. 
No hazard. 
Q105 
S-c 
253 
S – D 
1 sec. 
F101 
F101 opened immediately. 
Q104, ZD104 damaged. 
No hazard. 
Q105 
S-c 
253 
D - G 
1 sec. 
F101 
F101 opened immediately. 
Q104 damaged. 
No hazard. 
U101 
S-c 
253 
Pin 2 - 4 
1 sec 
F101 
F101 opened immediately. 
U101, ZD105 damaged. 
No hazard. 
C108 
S-c 
253 
30 min 
F101 
1,40 A 
Normal operated. 
Input current stabilised at 1,20A. 
Q1, Q2 damaged. 
R123 opened. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 
Page of 53
Display