Read Harman Kardon DPR 2005 EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 37 of 41 -
Order
No.
24776
FAULT CONDITION TESTS
P
Ambient temperature
25,5 °C
Rated voltage
230V~
Remarks
-
Comp.
No
No
Fault Test
V
Point Test
time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
BD101
S-c
253
AC - (+)
1 sec.
F101
-
F101 opened immediately.
No hazard.
No hazard.
BD101
S-c
207
AC - (+)
1 sec.
F101
-
F101 opened immediately.
No hazard.
No hazard.
C106
S-c
253
-
1 sec.
F101
-
F101 opened immediately.
No hazard.
No hazard.
C106
S-c
207
-
14 sec.
F101
3,60 A
F101 opened After 14 sec.
C107 damaged.
No hazard.
C107 damaged.
No hazard.
C107
S-c
253
-
1 sec.
F101
-
F101 opened immediately.
No hazard.
No hazard.
C107
S-c
207
-
17 sec.
F101
9,30 A
F101 opened After 17 sec.
C106 damaged.
No hazard.
C106 damaged.
No hazard.
Q102
S-c
253
S – D
1 sec.
F101
-
F101 opened immediately.
Q103, ZD102 damaged.
No hazard.
Q103, ZD102 damaged.
No hazard.
Q102
S-c
253
D - G
1 sec.
F101
-
F101 opened immediately.
Q103, ZD101 damaged.
No hazard.
Q103, ZD101 damaged.
No hazard.
Q105
S-c
253
S – D
1 sec.
F101
-
F101 opened immediately.
Q104, ZD104 damaged.
No hazard.
Q104, ZD104 damaged.
No hazard.
Q105
S-c
253
D - G
1 sec.
F101
-
F101 opened immediately.
Q104 damaged.
No hazard.
Q104 damaged.
No hazard.
U101
S-c
253
Pin 2 - 4
1 sec
F101
-
F101 opened immediately.
U101, ZD105 damaged.
No hazard.
U101, ZD105 damaged.
No hazard.
C108
S-c
253
-
30 min
F101
1,40 A
Normal operated.
Input current stabilised at 1,20A.
Q1, Q2 damaged.
R123 opened.
No hazard.
Input current stabilised at 1,20A.
Q1, Q2 damaged.
R123 opened.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
Click on the first or last page to see other DPR 2005 service manuals if exist.