Read Harman Kardon AVR 505 (serv.man13) EMC - CB Certificate online
-
IEC 60065, 6th edition : 1998
-
- Page 25 of 37 -
Order
No.
11151
15 TERMINALS
P
15.1.1
Mains plug, appliance inlet,
interconnection couplers and mains
socket-outlet meet the appropriate
standard
interconnection couplers and mains
socket-outlet meet the appropriate
standard
See list below.
P
Component Manufacturer
Type
Standard
Certified
Remarks
sheet
by
(colour
etc.)
Mains plug
Kenic Electric Mfg.
KE-21
IEC60884-1
VDE
2.5A 250V~, black
Mains
socket- outlet
socket- outlet
Dae Ryung Elect.
A3-04-D006
IEC60884-1
NEMKO
2.5A 250V~, black
Mains sockets and interconnection
couplers
couplers
The socket outlet on the Class II apparatus does only
permit connection of other Class II apparatus.
permit connection of other Class II apparatus.
P
Overload protection for
socket-outlets
socket-outlets
Overload protection provided with a fuses,
F901, F902: T2.5A 250V
F901, F902: T2.5A 250V
P
15.1.2
Connectors for antenna, earth,
audio, video or data:
audio, video or data:
P
No risk of insertion in mains
socket-outlets
socket-outlets
Only phono/RCA, Mini jack, Optical, Antenna and S-video
terminals used. Banana plug type speaker terminal also
used, but they are accepted due to below note.
Note:
Banana plug type speaker terminals are blocked in their
axial holes to prevent use of plugs that can make
permanent contact with a mains socket outlet.
terminals used. Banana plug type speaker terminal also
used, but they are accepted due to below note.
Note:
Banana plug type speaker terminals are blocked in their
axial holes to prevent use of plugs that can make
permanent contact with a mains socket outlet.
P
Sockets for audio and video circuits
indicated with the symbol of 5.2.b.
indicated with the symbol of 5.2.b.
No sockets indicated with the symbol
N
15.1.3
Output terminals of AC adaptors or
similar devices not compatible with
household mains socket-outlets
similar devices not compatible with
household mains socket-outlets
N
15.2
Provision for protective earthing
Class II apparatus
N
Accessible conductive parts of
Class I equipment reliably connected
to earth terminal, within equipment.
Class I equipment reliably connected
to earth terminal, within equipment.
N
Switches or fuses in protective earth
circuits
circuits
N
Class I supply apparatus with non-
hazardous live output voltage: output
circuit not connected to earth
hazardous live output voltage: output
circuit not connected to earth
N
Protective earth conductors correctly
coloured
coloured
N
Click on the first or last page to see other AVR 505 (serv.man13) service manuals if exist.